UFS 4-023-07 2 February 2026 UNIFIED FACILITIES SUPPLEMENT (UFS) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED DESIGN TO RESIST DIRECT FIRE WEAPONS EFFECTS UFS 4-023-07 2 February 2026 FOREWORD Unified Facilities Supplements (UFS) provide non-mandatory, supplemental information in support of Unified Facilities Criteria (UFC). Only UFC establish enforceable criteria. UFS are For Information Only (FIO) and exist to help users understand and apply UFC requirements. The purpose of UFS is to offer procedural guidance, best practices, lessons learned, examples, and explanatory materials that clarify how to meet UFC criteria. They may include step-by-step procedures, checklists, illustrations, or decision aids, but they do not create new requirements or modify UFC content. UFS are developed
of the equations in this chapter. The exception to that is Equation 5-4 for steel, which includes angles of obliquity. Another option is to provide high parapets that block sightlines to the roof. For this level of protection those parapets would either be sufficiently constructed to provide all the penetration resistance necessary or the combination of the parapet and the roof material would have to provide the resistance. Refer to the wall section of this chapter to design the parapets. Figure 5-10 shows a raised parapet configuration. UFS 4-023-07 2 February 2026 49 Figure 5-10. Raised Parapets UFS 4-023-07 2 February 2026 50 APPENDIX A REFERENCES ASTM INTERNATIONAL https://www.astm.org/ ASTM F 1233-08, Standard Test Method for Security Glazing Materials and Systems, 2013 DEPARTMENT OF
s. In addressing window layout and placement, consider layouts and placements that do not allow sight lines to assets from outside the building using window configurations such as those shown in Figures 5-4 and 5-5. Alternatively, arrange rooms to ensure that potentially targeted assets cannot be seen through the windows or block sight lines through windows using screening materials such as fences or vegetation as described in Chapter 4. UFS 4-023-07 2 February 2026 40 Figure 5-4. Narrow Obliquely Recessed Windows Figure 5-5. Elevated Windows UFS 4-023-07 2 February 2026 41 5-4.2.1 Low Level of Protection Alternatives. An alternate approach is to design windows to limit sight lines through them by using translucent or figured glazing that allows light in but is not sufficiently transparent
DoD High Risk Personnel (HRP) UFC 3-530-01 Interior and Exterior Lighting Systems UFC 3-600-01 Fire Protection Engineering for Facilities UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings UFC 4-010-02 DoD Minimum Antiterrorism Standoff Distances for Buildings (FOUO) [Inactive] UFC 4-020-01 DoD Security Engineering Facilities Planning Manual UFC 4-021-02 Electronic Security Systems UFC 4-022-01 Security Engineering: Entry Control Facilities / Access Control Points UFC 4-022-02 Selection and Application of Vehicle Barriers UFC 4-026-01 Design to Resist Forced Entry UFS 4-023-07 Design to Resist Direct Fire Weapons Effects DoD 0.2000.12-H, DoD Antiterrorism Handbook UFS 4-010-03 3 February 2026 68 DEPARTMENT OF STATE United States Department of State Overseas Security Advisory Co
position should detonate incoming contact-fuzed munitions. These screens supplement the protection inherent in the protected structure or position and reduce structure damage. The screen may be wood, sheet steel, fencing, metal mesh, and other acceptable materials. It may be solid material or open screen. Use open screens (e.g., chain link fence or metal mesh) when observation through the screen is required. For information on constructing and siting predetonation screens, refer to GTA 90- 01-011 and UFC 4-023-07. Note: Predetonation layers may provide overhead protection for expeditionary and temporary structures when incorporated with adequate shielding layers. 5.6.9. Unconventional Hardening. In extreme, time-critical situations, previously discussed hardening methods may not be suitabl
otification Systems UFC 4-021-02 Security Engineering: Electronic Security Systems UFC 4-022-01 Entry Control Facilities/Access Control Points UFC 4-022-02 Design and Selection of Vehicle Barriers UFC 4-022-03/ Design of Security Fencing, Gates, Barriers, and MIL-HDBK-1013/10 Guard Facilities UFC 4-023-03 Design of Buildings to Resist Progressive Collapse UFC 4-023-04 Design of Windows to Resist Blast, Ballistics, and Forced Entry UFC 4-023-07 Design to Resist Direct Fire Weapons Effects UFC 4-026-01 Design to Resist Forced Entry UFC 4-027-01 Design of Deployed Operational Bases to Mitigate Terrorist AttacksAFH 10-222 Volume 14 1 August 2008 21 Chapter 2 FIGHTING POSITIONS 2.1. Overview. Fighting positions are fortified structures used for protection against hostile fire. They can also be
: https://assist.dla.mil -- Downloaded: 2026-07-20T01:48Z Check the source to verify that this is the current version before use. MIL-HDBK-502B 63 5.8.3.1.3 When Required. The early fielding analysis is conducted during the EMD phase. 5.8.3.1.4 Applicable LPD Summaries. LSA-007, LSA-014, LSA-023, LSA-024, LSA-025, LSA-026, LSA-036, LSA-058, and LSA-075. 5.8.3.1.5 Associated Standards. SAE TA-STD-0017A, International Standards Organization (ISO) 55000 5.8.3.1.6 Associated Products. Early Fielding Report, Materiel Fielding Plan, Manpower and Personnel Estimate, Supportability Analysis Report, Survivability Analysis Report, and Risk Assessment Report 5.8.3.1.7 Responsibility. The contractor is responsible for ensuring early fielding analysis is performed during EMD. This analysis should be co
ailable for download) UFC 4-022-03 Security Fences and Gates wbdg.org (available for download) UFC 4-023-07 Design to Resist Direct Fire Weapons Effects wbdg.org (available for download) UFGS 34 71 13.19 Active Vehicle Barriers wbdg.org (available for download) UFGS 34 41 26.00 10 Access Control Point Control System wbdg.org (available for download) NATIONAL DESIGN STANDARDS Title Source American Association of State Highway and Transportation Officials (AASHTO) A Policy on Geometric Design of Highways and Streets (Greenbook) Transportation.org (available for purchase) AASHTO Roadside Design Guide Transportation.org (available for purchase) AASHTO Manual for Assessing Safety Hardware (MASH) Transportation.org (available for purchase) Architectural Barrier Act (ABA) Accessibility Standard F