I need to clarify what you're asking about UFS 3-201-01. The passages provided contain excerpts from UFS 3-201-01 but do not include a specific question or numbered item within that document.

UFS 3-201-01 is a Unified Facilities Supplement that provides non-mandatory, supplemental information supporting UFC 3-201-01 (Civil Engineering). It is "For Information Only (FIO)" and does not create new enforceable requirements—only UFC establish enforceable criteria [UFS 3-201-01 Foreword].

The excerpts included address:
- Motorcycle parking design (rigid pavement surfaces, location near entrances or lot corners, signage/markings) [UFS 3-201-01 1-6.7.4]
- Bicycle facilities (references AASHTO GBF best practices) [UFS 3-201-01 1-6.7.5]
- Storm drainage systems (Rational Formula guidance) [UFS 3-201-01 Chapter 2]
- Parking space requirements for various facilities (dormitories, exchanges, dining facilities, etc.) [UFS 3-201-01]

If you have a specific question about UFS 3-201-01 content

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
Show the 8 source passage(s) this answer is built from
UFS 3-201-01 as of 2026-06-05 · official source ↗

UFS 3-201-01 05 June 2026 UNIFIED FACILITIES SUPPLEMENT (UFS) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED CIVIL ENGINEERING UFS 3-201-01 05 June 2026 FOREWORD Unified Facilities Supplements (UFS) provide non-mandatory, supplemental information in support of Unified Facilities Criteria (UFC). Only UFC establish enforceable criteria. UFS are For Information Only (FIO) and exist to help users understand and apply UFC requirements. The purpose of UFS is to offer procedural guidance, best practices, lessons learned, examples, and explanatory materials that clarify how to meet UFC criteria. They may include step-by-step procedures, checklists, illustrations, or decision aids, but they do not create new requirements or modify UFC content. UFS are developed by Discipline Working Groups (DW

UFS 3-201-01 as of 2026-06-05 · official source ↗

Motorcycles. Motorcycle parking surfaces are typically designed as rigid pavements to prevent kickstands from penetrating bituminous pavement in warm weather. • Locate parking close to building entrances. • Locate parking in parking lot corners. • Provide signage and pavement markings. 1-6.7.5 Bicycle Facilities. Use Best Practices document, AASHTO GBF for additional design guidance. UFS 3-201-01 05 June 2026 12 CHAPTER 2 STORM DRAINAGE SYSTEMS 2-1 DESIGN CRITERIA. For additional design guidance, consult Best Practices, as indicated in UFC 3-201-01, Appendix A. and manufacturer’s data. 2-1.1 Rational Formula. Use the Rational Formula to determine peak flow from small watersheds. The Rational Formula is based on the following assumptions: • Peak flow occurs when the entire watershed is con

UFS 3-201-01 as of 2026-06-05 · official source ↗

ommunity Shopping Center, including such elements as Main Exchange, Miscellaneous Shops, Restaurant, Commissary Stores, Food Sales, Bank, Theater, Post Office 4 percent of customers served Dental Clinic Parking 3 spaces per treatment room Dormitories, BEQ, Enlisted Unaccompanied Personnel Housing 70% of design capacity Enlisted Personnel Dining Facilities (Staff Parking) 38 percent of employees Enlisted Personnel Dining Facilities (Patron Parking) 8 percent of enlisted personnel served UFS 3-201-01 05 June 2026 9 Facility Number of Parking Spaces Exchanges, Main, when not included in a Community Shopping Center 25 percent of customers served Family Housing 2.5 spaces per living unit Field House, combined with Football and Baseball Facilities 1 percent of military strength served Fire Stati

UFS 2-100-01 as of 2026-01-16 · official source ↗

.esd.whs.mil/Directives/issuances/dodd/ DoDD 3020.40, Mission Assurance (MA) DoD Instructions: https://www.esd.whs.mil/Directives/issuances/dodi/ DoDI 3020.45, Mission Assurance (MA) Construct DoDI 4165.70, Real Property Management DoDI 4170.11, Installation Energy Management DoDI 4715.28, Military Installation Resilience UFS 2-100-01 16 January 2026 81 UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-201-01, Civil Engineering UFC 3-201-02, Landscape Architecture UFC 3-210-10, Low Impact Development UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-410-01, Heating, Ventilating, and Air-Conditioning Systems UFC 4-010-01, DoD Minimum Antiterrorism Standard for Buildi

UFS 1-201-02 as of 2025-07-28 · official source ↗

Install GFCI receptacle GFCI receptacles fail to trip.  Yes  No 4-6.2.11 Replace GFCI receptacle UFS 1-201-02 28 July 2025 87 CONDITION ASSESSED CONDITIONS FOR FURTHER INFORMATION SEE ALLOWED FIELD MITIGATION RECORD ACTUAL CONDITIONS AND ACTIONS TAKEN IN SPACE PROVIDED BELOW ASSESSED ITEM. Circuit lockout requirements Appropriate circuit lock-out procedures exist.  Yes  No 4-6.1.11 Develop procedures to properly lock out and tag out electrical systems prior to occupation per UFC 3-520- 01. UFS 1-201-02 28 July 2025 88 Additional Notes on Electrical System Issues and Mitigation Actions: UFS 1-201-02 28 July 2025 89 TELECOMMUNICATION SYSTEMS INSPECTOR NAME: CONDITION ASSESSED CONDITIONS FOR FURTHER INFORMATION SEE ALLOWED FIELD MITIGATION RECORD ACTUAL CONDITIONS AND ACTIONS TAKEN IN SPA

UFC 4-141-03 as of 2024-12-09 · official source ↗

rs and switches for redundancy Not Required Required Required UFC 4-141-03 09 December 2024 9 Grade 2 Grade 3 Grade 4 Patch panels, outlets, and cabling to be labeled per ANSI/TIA-606-D. Cabinets and racks to be labeled on front and rear. Required Required Required Patch cords and jumpers to be labeled on both ends with the name of the connection at both ends of the cable Required Required Required Patch panel and patch cable documentation compliant with ANSI/TIA-606-D. Not Required Required Required ARCHITECTURAL Parking Separate visitor and employee parking areas IAW UFC 3-201-01 IAW UFC 3-201-01 IAW UFC 3-201-01 Separate from loading docks IAW UFC 3-201-01 IAW UFC 3-201-01 IAW UFC 3-201-01 Proximity of visitor parking to data center perimeter building walls IAW UFC 4-020-01 IAW UFC 4-02

CFETP 2W0X1C1 · para 2.3.4 as of 2025-05-27 · open official PDF ↗

ill 5 Skill Core Tasks Level Level Course CDC 1 MUNITIONS SYSTEMS CAREER FIELD TR: AFMAN 21-200, DAFMAN 21-201; AFH 36-2618; AFECD (see B.1) 1.1 Munitions and Weapons Career Field 5 A B 1.2 Progression/duties within the 2W0X1 career field 5 A B 2 SECURITY 2.1 Security classification levels TR: DAFMAN 21- - - 201; DoDI 5200.01 2.2 OPSEC vulnerabilities for 2W0X1 TR: DoDM 5200.01_ AFMAN - B 16-1404V1-3; AF Security Munitions Classification Guides; DoDI 5200.01 2.3 Munitions Security AFMAN 21-200; DoDM 5100.76_AFMAN 31-101V2; DoDM 5200.01_ AFMAN 16-1404V1-3 2.3.1 Controlled/restricted areas 5 A B 2.3.2 Entry control point 5 A B 2.3.3 Escort duties A - 2.3.4 Controlled Inventory Item Code (CIIC)/Risk codes TR: WebFLIS 5 A B 2.3.5 Transportation/storage of munitions 5 A B 2.3.6 Intrusion detect

TO 00-20-2 · para 11.3.99 as of 2024-12-12 · official source ↗

ups the UF and QPA of the next higher assembly shall be used. For total aircraft roll ups, the QPA and UF shall be set to one. 11.3.97 Mean Time Between Maintenance Type 6 (No Defect) (MTBM-6). if the TYPE EQUIPMENT equals “A” or “E” then 11.3.98 Mean Time Between Maintenance Type 6 (No Defect) (MTBM-6). if TYPE EQUIPMENT is not equal “A,” “E,” “C,” or “R” then NOTE USAGE FACTOR (UF) and QUANTITY PER APPLICATION (QPA) shall come from the WUC table for 5-digit WUCs. For 2-, 3-, and 4-digit WUC roll ups the UF and QPA of the next higher assembly shall be used. For total aircraft roll ups, the QPA and UF shall be set to one. 11.3.99 Mean Time Between Maintenance Type 6 (No Defect) (MTBM-6). TO 00-20-2 11-24 if the TYPE EQUIPMENT equals “A,” or “E,” then NOTE USAGE FACTOR (UF) and QUANTITY PER

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.