Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.
UFS 1-300-02 22 September 2025 UNIFIED FACILITIES SUPPLEMENT (UFS) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) FORMAT STANDARD UFS 1-300-02 22 September 2025 FOREWORD Unified Facilities Supplements (UFS) provide non-mandatory, supplemental information in support of Unified Facilities Criteria (UFC). Only UFC establish enforceable criteria. UFS are For Information Only (FIO) and exist to help users understand and apply UFC requirements. The purpose of UFS is to offer procedural guidance, best practices, lessons learned, examples, and explanatory materials that clarify how to meet UFC criteria. They may include step-by-step procedures, checklists, illustrations, or decision aids, but they do not create new requirements or modify UFC cont
ns, or decision aids, but they do not create new requirements or modify UFC content. UFS are developed by Discipline Working Groups (DWGs) and published by the Military Services under MIL-STD-3007. Because they are not criteria, they do not require Coordinating Panel (CP) or Engineering Senior Executive Panel (ESEP) approval. UFS content may be referenced or incorporated into project documents at the discretion of project delivery teams but are not binding unless explicitly included in contract requirements. For Service-specific supplemental guidance, refer to Facilities Supplements (FS). UFS 1-300-02 22 September 2025 i UNIFIED FACILITIES SUPPLEMENT (UFS) UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) FORMAT STANDARD TABLE OF CONTENTS CHAPTER 1 INTRODUCTION ...............................
e the specification process, reduce errors, and improve communication among architects, engineers, contractors, and other stakeholders involved in design and construction projects. 1-2 REISSUES AND CANCELS. This UFS reissues and cancels UFC 1-300-02, Unified Facilities Guide Specifications (UFGS) Format Standard, dated 1 April 2014 with Changes 1-3. 1-3 PURPOSE AND SCOPE. This UFS provides guidance for the preparation of UFGS and establishes the general content and format of UFGS and project specifications. Each DWG is responsible for the technical content, format, and overall quality of their UFGS. Publication of UFGS is available by electronic media, not proprietary, and at no cost to the user. Preparers for both UFGS Masters and project specifications must use this UFS. Specific guidanc
80B. 1. The cable racking system must be rated for 300 lbs. Cable racks must be placed on all manhole walls whether currently used or not. Cables must be tied to racks using cable ties. 2. Ground all metallic parts of the manhole with a #4 bare stranded ground wire. UFS 3-535-02 2 February 2026 185 Figure 80B. Cable Rack Option Detail UFS 3-535-02 2 February 2026 186 7-10.3 Figure 80C. 7-10.3.1 Drawing Notes for Figure 80C. 1. Provide a brass survey marker with ID text stamped into it for each airfield lighting manhole. UFS 3-535-02 2 February 2026 187 Figure 80C. Brass Survey Marker Detail Manhole Foldout Diagrams and Circuit Schedule. UFS 3-535-02 2 February 2026 188 7-10.4 Figures 80D, 80E. 7-10.4.1 Notes to Designer. 1. The Manhole Foldout Diagram indicates the number and size of duct/
son through the area of UFS 1-201-02 28 July 2025 104 Assembly use, deducting area for access/circulation paths that are maintained in the space. d. Business: Use number of desks. e. Factory/Industrial: Use 300 sq. ft. (27.9 sq. m.) per person, using the overall area of the occupancy. f. Storage: Use 300 sq. ft. (27.9 sq. m.) per person, using the overall area of the occupancy. UFS 1-201-02 28 July 2025 105 APPENDIX E REFERENCES DEPARTMENT OF THE ARMY TM 3-34.70/MCRP 3-17.7E, Plumbing, Pipe Fitting, and Sewerage https://armypubs.army.mil/epubs/DR_pubs/DR_a/pdf/web/tm3_34x70.pdf DEPARTMENT OF DEFENSE GTA 90-01-011, Joint Forward Operations Base (JFOB) Protection Handbook https://armypubs.army.mil/ProductMaps/PubForm/GTA.aspx Joint Publication 3-0, Joint Operations https://irp.fas.org/doddir
pools, or other humid spaces. • Light room surfaces to balance luminance ratios. • Minimize shadows by providing diffuse lighting, especially at lockers and counters. • Refer to UFC 4-740-02 for additional requirements and considerations regarding recreational spaces in fitness centers. • For locker rooms greater than 300 square feet, means of egress must comply with NFPA 101 for passageways leading to an exit. 1-6 MAINTENANCE SPACES. 1-6.1 Vehicle Maintenance Areas. UFS 3-530-01 05 June 2026 48 1-6.1.1 Control Requirements. Manual Control Manual OFF with scene wallstation with at least three preset scenes: full ON, lights dimmed between 30% and 70% of full lighting power, and OFF. Occupancy/Vacancy Manual ON Automatically dimmed by at least 50% after 20 minutes of vacancy Time Schedule Sc
UFC 1-200-01 - DoD Building Code (General Building Requirements) UFC 1-300-01 - Criteria Format Standard UFC 1-300-02 - Unified Facilities Guide Specifications (UFGS) Format Standard (Copies of these documents are available online at https://www.wbdg.org/ffc/dod/unified-facilities- criteria-ufc.) OFFICE OF MANAGEMENT AND BUDGET Source: https://assist.dla.mil -- Downloaded: 2026-07-20T01:47Z Check the source to verify that this is the current version before use. MIL-STD-3007G 2 OMB Circular A-119 - Federal Participation in the Development and Use of Voluntary Consensus Standards and in Conformity Assessment Activities, dated 10 February 1998. (Copies of these documents are available online at https://www.whitehouse.gov/wp- content/uploads/2017/11/Circular-119-1.pdf.) PUBLIC LAW Public Law
dev = 0.657 1.174 1.199 CV1= 0.006 0.011 0.012 CV1 (pooled) = 0.010 * Rejected as an outlier—this value did not pass the outlier T-test at the 99% confidence level. Test level 0.1 × Percent rec. µg taken µg found 0.200 0.2509 125.5 0.200 0.2509 125.5 0.200 0.2761 138.1 0.200 0.2258 112.9 0.200 0.2258 112.9 0.200 0.1881 94.1 n= 6 mean = 118.2 std dev = 15.1 CV1= 0.128 Table VI—Analytical Method Recovery[AAS-HGA analysis] Test level 0.5 × Percent rec. ng taken 1.0 × Percent rec. ng taken 2.0 × Percent rec. ng taken ng found ng found ng found 75 71.23 95.0 150 138.00 92.0 300 258.43 86.1 75 71.47 95.3 150 138.29 92.2 300 258.46 86.2 75 70.02 93.4 150 136.30 90.9 300 280.55 93.5 75 77.34 103.1 150 146.62 97.7 300 288.34 96.1 75 78.32 104.4 150 145.17 96.8 300 261.74 87.2 75 71.96 95.9 150 144.
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.