UFS 1-300-01 14 January 2026 UNIFIED FACILITIES SUPPLEMENT (UFS) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED CRITERIA FORMAT STANDARD UFS 1-300-01 14 January 2026 FOREWORD Unified Facilities Supplements (UFS) provide non-mandatory, supplemental information in support of Unified Facilities Criteria (UFC). Only UFC establish enforceable criteria. UFS are For Information Only (FIO) and exist to help users understand and apply UFC requirements. The purpose of UFS is to offer procedural guidance, best practices, lessons learned, examples, and explanatory materials that clarify how to meet UFC criteria. They may include step-by-step procedures, checklists, illustrations, or decision aids, but they do not create new requirements or modify UFC content. UFS are developed by Discipline Worki
document. Unless otherwise specified, the most recent edition of the referenced publication applies. Refer to UFC 1-200-01, for the applicable publication date for International Building Code®. Refer to UFC 1- UFS 1-300-01 14 January 2026 5 200-02, for the applicable publication date for ASHRAE Standard 90.1, Energy Standard for Buildings Except Low-Rise Residential Buildings. UFS 1-300-01 14 January 2026 6 CHAPTER 2 STYLE AND FORMAT 2-1 INTRODUCTION. The style and format are designed to facilitate ease of preparation and use. The DWG is responsible for the format, technical content, and overall quality of its criteria document in accordance with the following guidelines: • Provide documents that meet the format and content requirements in accordance with UFC 1-300-01. • Provide technical
developing or coordinating the project-level effort to update a criteria document. The technical proponent can be a DWG or FWG member or other member of a participating organization or technical agency. (MIL-STD-3007) UFS 1-300-01 14 January 2026 38 Technical Representative: Technical working-level representative from another participating organization for a particular document assigned to assist the technical proponent in the DoD component review, unification, and maintenance of a criteria document. (MIL-STD-3007) UFS 1-300-01 14 January 2026 39 APPENDIX C REFERENCES GOVERNMENT Federal Plain Language Guidelines https://www.plainlanguage.gov/guidelines/ Principles of Clear Writing https://www.archives.gov/federal-register/write/legal-docs/clear-writing.html SD-10, Guide for Identification
.8 m / 12.5 ft. span) 4 225 mm ( 9 in) lightly reinforced concrete (6 m / 20 ft. span) 5 225 mm ( 9 in) moderately reinforced concrete (1.5 m / 5 ft. span) 6 225 mm ( 9 in) moderately reinforced concrete (3.8 m / 12.5 ft. span) 7 225 mm ( 9 in) moderately reinforced concrete (6 m / 20 ft. span) 8 225 mm ( 9 in) heavily reinforced concrete (6 m / 20 ft. span) 9 300 mm ( 12 in) moderately reinforced concrete (6 m / 20 ft. span ) 10 UFS 4-010-01 1 July 2026 246 Hardened Roofs (continued) 300 mm ( 12 in) heavily reinforced concrete (6 m / 20 ft. span) 11 Sacrificial Roofs Conventional built up roofing at 2 m (6 ft) 1 Standing seam metal roof + 50 mm (2 in) extruded polystyrene insulation + 50 mm (2 in) corrugated steel deck at 2 m (6 ft) 2 UFS 4-010-01 1 July 2026 247 Table C-10 Direct Fire We
ire type Occupancy/Vacancy Manual ON with automatic full OFF after 20 minutes of vacancy Time Schedule None Daylight Automatic responsive daylight dimming when daylight is present Zoning Provide separate control for downlight and ambient uplight 1-1.8.2 Performance Requirements. Target Criteria Daytime/Nighttime Average Horizontal Illuminance 20 fc (300 lux) at 2’-6” (762 mm) AFF Horizontal Illuminance Uniformity 3:1 average to minimum UFS 3-530-01 05 June 2026 15 1-1.8.3 Critical Design Issues. • Minimize glare with solutions such as a diffuse lens, regressed lens, indirect optics, and/or shielded louvers. • Light room surfaces to balance luminance ratios. UFS 3-530-01 05 June 2026 16 1-1.9 Building Entry Vestibules. 1-1.9.1 Control Requirements. Manual Control None required if remote loc
son through the area of UFS 1-201-02 28 July 2025 104 Assembly use, deducting area for access/circulation paths that are maintained in the space. d. Business: Use number of desks. e. Factory/Industrial: Use 300 sq. ft. (27.9 sq. m.) per person, using the overall area of the occupancy. f. Storage: Use 300 sq. ft. (27.9 sq. m.) per person, using the overall area of the occupancy. UFS 1-201-02 28 July 2025 105 APPENDIX E REFERENCES DEPARTMENT OF THE ARMY TM 3-34.70/MCRP 3-17.7E, Plumbing, Pipe Fitting, and Sewerage https://armypubs.army.mil/epubs/DR_pubs/DR_a/pdf/web/tm3_34x70.pdf DEPARTMENT OF DEFENSE GTA 90-01-011, Joint Forward Operations Base (JFOB) Protection Handbook https://armypubs.army.mil/ProductMaps/PubForm/GTA.aspx Joint Publication 3-0, Joint Operations https://irp.fas.org/doddir
Schedule C—Quantities of radioactive materials requiring consideration of the need for an emergency plan for responding to a release.. Radioactive material 1 Release fraction Quantity (curies) Actinium-228 0.001 4,000 Americium-241 .001 2 Americium-242 .001 2 Americium-243 .001 2 Antimony-124 .01 4,000 Antimony-126 .01 6,000 Barium-133 .01 10,000 Barium-140 .01 30,000 Bismuth-207 .01 5,000 Bismuth-210 .01 600 Cadmium-109 .01 1,000 Cadmium-113 .01 80 Calcium-45 .01 20,000 Californium-252 .001 9 (20 mg) Carbon-14 (non-carbon dioxide) .01 50,000 Cerium-141 .01 10,000 Cerium-144 .01 300 Cesium-134 .01 2,000 Cesium-137 .01 3,000 Chlorine-36 .5 100 Chromium-51 .01 300,000 Cobalt-60 .001 5,000 Copper-64 .01 200,000 Curium-242 .001 60 Curium-243 .001 3 Curium-244 .001 4 Curium-245 .001 2 Europium-152 .01 500 Europium-154 .01 400 Europium-155 .01 3,000 Germanium-68 .01 2,000 Gadolinium-153 .01 5,
MDTINST M13482.4B 5 July 2013 ROUNDSLINGS NSN PART NUMBER CAPACITY LENGTH 1670-01-388-6789 PRS 2E008 5,300-pound 8 foot 1670-01-388-3845 PRS 2E017 5,300-pound 17 foot 1670-01-388-8480 PRS 3E008 8,400-pound 8 foot 1670-01-388-8479 PRS 3E017 8,400-pound 17 foot 1670-01-388-3917 PRS 5E030 13,200-pound 30 foot 1670-01-388-3901 PRS 7E065 21,200-pound 65 foot 1670-01-388-3965 PRS 7E070 21,200-pound 70 foot 5,000- AND 10,000-POUND CAPACITY CARGO NETS AND COMPONENTS NSN PART NUMBER DESCRIPTION QTY PER NET 1670-01-058-3811 6018-5 Net, 5,000-pound capacity, LIN N02776, TAMCN J3121 1 ea 1670-01-058-3810 6018-10 Net, 10,000-pound capacity, LIN N02708, TAMCN J3120 1 ea 1670-01-070-5276 6019 Apex fitting 1 ea 1670-01-067-9989 6020 Hook 4 ea 4020-01-118-5826 6018-15 Repair cord, used on part no. 6018-5 A