Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

I don't have a specific question to answer about UFM 4-150-08.

The passages provided show that UFM 4-150-08 is a Unified Facilities Manual (current as of 10 March 2026) addressing Mooring Hardware Inspection [UFM 4-150-08]. The manual is for information only (FIO) and provides non-mandatory guidance to support UFC requirements; only UFC establish enforceable requirements [UFM 4-150-08 Foreword].

The document includes inspection procedures, mooring hardware profiles, condition rating scales, and a glossary of acronyms and references [UFM 4-150-08].

Please provide a specific question about mooring hardware inspection, and I will answer it from these passages.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
Show the 8 source passage(s) this answer is built from
UFM 4-150-08 as of 2026-03-10 · official source ↗

f an approaching storm. See Table 3-4 in UFC 4-159-03 for an explanation of mooring service types (MST). UFM 4-150-08 10 March 2026 7 Figure 2-1 Mooring Hardware Inspection Process Establish Mooring Hardware Inspection Program Gather Existing Data Level 1 Inspection as Needed Level 2 Baseline Inspection and Report Access Baseline Conditions Formulate plan and Scope of Work for Implementing Level 3 Inspection Conduct Level 3 Inspection Update Level 2 Inspection and Continue Higher Level Inspection Program UFM 4-150-08 10 March 2026 8 Figure 2-2 Mooring Hardware Inspection Record UFM 4-150-08 10 March 2026 9 UFM 4-150-08 10 March 2026 10 Figure 2-3 Typical Profiles of Mooring Hardware UFM 4-150-08 10 March 2026 11 Figure 2-4 Condition Rating Scale for Mooring Hardware Example of Condition Mo

UFM 4-150-08 as of 2026-03-10 · official source ↗

UFM 4-150-08 10 March 2026 UNIFIED FACILITIES MANUAL (UFM) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED MOORING HARDWARE INSPECTION UFM 4-150-08 10 March 2026 FOREWORD Unified Facilities Manuals (UFM) provide non-mandatory, informational guidance in support of Unified Facilities Criteria (UFC) with a specific focus on facilities operations, and maintenance. Only UFC establish enforceable requirements. UFM are For Information Only (FIO) and exist to help users understand and apply UFC requirements. The purpose of UFM is to share operational procedures, maintenance practices, and practical examples that support effective implementation of UFC criteria during operations and maintenance activities. UFM may include recommended procedures, checklists, illustrations, or explanatory materia

UFM 4-150-08 as of 2026-03-10 · official source ↗

4-150-08 10 March 2026 35 APPENDIX B GLOSSARY B-1 ACRONYMS. AFCEC Air Force Civil Engineer Center ASTM American Society for Testing and Materials ASQ American Society for Quality BIA Bilateral Infrastructure Agreement DoD Department of Defense EXWC Engineering and Expeditionary Warfare Center HNFA Host Nation Funded Construction Agreements HQUSACE Headquarters, U.S. Army Corps of Engineers MLLW Mean Lower Low Water MST Mooring Service Type NAVFAC Naval Facilities Engineering Command P.E. Professional Engineer PFD Personal Floatation Device SOFA Status of Forces Agreements UFC Unified Facilities Criteria UFM Unified Facilities Manual U.S. United States USCG United States Coast Guard UFM 4-150-08 10 March 2026 36 APPENDIX C REFERENCES C-1 GOVERNMENT PUBLICATIONS. NAVAL FACILITIES ENGINEERIN

UFM 3-460-03 as of 2026-03-09 · official source ↗

r Fire Resistant Tanks for Flammable and Combustible Liquids UL 2085, Standard for Protected Aboveground Tanks for Flammable and Combustible Liquids UNIFIED FACILITIES CRITERIA UFC 3-110-03, Roofing UFC 3-430-07, Operations and Maintenance: Inspection and Certification of Boilers and Unfired Pressure Vessels UFM 3-460-03 9 March 2026 404 UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-575-01, Lightning and Static Electricity Protection Systems UFC 3-600-01, Fire Protection Engineering for Facilities UFM 3-570-06, Operation and Maintenance: Cathodic Protection Systems UFM 3-601-02, Operation and Maintenance: Inspection, Testing, and Maintenance of Fire Protection Systems UFM 4-150-07, Maintenance and Operation: Maintenance of Waterfront Facilities UFM 4-150-08, Mooring Hardware Inspec

UFM 3-270-08 as of 2026-02-25 · official source ↗

150/5380-9, Guidelines and Procedures for Measuring Airfield Pavement Roughness UFM 3-270-08 25 February 2026 228 AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) https://store.transportation.org/ AASHTO Roadside Design Guide AASHTO Guidelines for Geometric Design of Low-Volume Roads AASHTO A Policy on Geometric Design of Highways and Streets AASHTO R 43, Standard Practice for Quantifying Roughness of Pavements ASTM INTERNATIONAL https://www.astm.org/standards-and-solutions/standards-publications ASTM E1926, Standard Practice for Computing International Roughness Index of Roads from Longitudinal Profile Measurements ASPHALT INSTITUTE (AI) https://my.asphaltinstitute.org/Shop/Product-Catalog MS-4, The Asphalt Handbook MS-17, Asphalt Overlays for Highway and Street

UFM 3-550-07 as of 2026-03-12 · official source ↗

transformer. UFM 3-550-07 12 March 2026 179 Figure D-1 S&C Vista Switchgear Notes for S&C Vista Tables: 1. The S&C Vista switchgear typically have CT ratios of 660:1, which should be confirmed. Minimum trip setting is 25 amperes. 2. Available E-speed settings are 25E, 30E, 40E, 50E, 65E, 80E, 100E, 125E, 150E, 175E, 200E, 250E, 300E, and 400E. 3. The factory-shipped default settings are 200E. UFM 3-550-07 12 March 2026 180 Table D-1 S&C VFI Settings to Provide Primary Protection for Individual Transformers – 2.4 kV Transformer 1-Phase Rating (kVA) Transformer 3-Phase Rating (kVA) 3-Phase Full Load Line Current E-Speed Setting (amperes) 15 45 10.83 25 25 75 18.04 25 37.5 112.5 27.06 30 50 150 36.08 40 75 225 54.13 65 100 300 72.17 80 167 500 120.28 125 --- 750 180.42 200 --- 1000 240.56 250

UFM 3-230-13 · para 0.26 as of 2026-02-05 · official source ↗

aCO3) (Tables A-5 and A-6) UFM 3-230-13 5 February 2026 206 Table A-1 Factor "A" for TDS TDS (ppm) Value of "A" 50 0.07 75 0.08 100 0.10 150 0.11 200 0.13 300 0.14 400 0.16 600 0.18 800 0.19 1000 0.20 1500 0.21 2000 0.22 2500 0.23 3000 0.24 4000 0.25 5000 0.26 UFM 3-230-13 5 February 2026 207 Table A-2 Factor "B" for Temperature °F F, Units Tens 0 2 4 6 8 30 -- 2.60 2.57 2.54 2.51 40 2.48 2.45 2.43 2.40 2.37 50 2.34 2.31 2.28 2.25 2.22 60 2.20 2.17 2.14 2.11 2.09 70 2.06 2.04 2.03 2.00 1.97 80 1.95 1.92 1.90 1.88 1.86 90 1.84 1.82 1.80 1.78 1.76 100 1.74 1.72 1.71 1.69 1.67 110 1.65 1.64 1.62 1.60 1.58 120 1.57 1.55 1.53 1.51 1.50 130 1.48 1.46 1.44 1.43 1.41 140 1.40 1.38 1.37 1.35 1.34 150 1.32 1.31 1.29 1.28 1.27 160 1.26 1.24 1.23 1.22 1.21 170 1.19 1.18 1.17 1.16 -- Find value of "B"

UFC 3-260-01 as of 2019-02-04 · official source ↗

.48 m (5100 ft) for 34:1 approach- departure surfaces N/A N/A Navy and Marine Corps airfields only N/A 1402.08 m (4600 ft) 1402.08 m (4600 ft) Navy and Marine Corps airfields only. Circular in shape, located 45.72 m (150 ft) above the established heliport or helipad elevation, defined by scribing an arc with a 1402.08 m (4600 ft) radius about the center point of the helipad 14 Elevation of horizontal surface H 45.72 m (150 ft) 45.72 m (150 ft) 45.72 m (150 ft) Navy and Marine Corps airfields only NOTES: 1. Metric units apply to new airfield construction and, where practical, modification to existing airfields and heliports, as discussed in paragraph 1-3.4. 2. The criteria in this manual are based on aircraft specific requirements and are not direct conversions from inch-pound (English) dim

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.