Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

UFC 4-911-01N is INACTIVE as of 16 January 2004 [UFC 4-911-01N foreword].

The document is marked inactive in the provided passages. For current guidance on Operations & Maintenance and Inactive Care and Closure of Shore Facilities, consult the active version or the official DoD source, as this criteria document is no longer in effect.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
NFPA standards (cited by reference)
NFPA 780 Installation of Lightning Protection Systems — cited by AFSOCI 32-1084 (sections 8.1.1, 8) · read at NFPA free access ↗
NFPA 33 — cited by AFSOCI 32-1084 · read at NFPA free access ↗

NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.

Show the 8 source passage(s) this answer is built from

cation INACTIVE UFC 4-911-01N 16 January 2004 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.) Therefore, the acquisition team must ensure compliance with the more stringent of the UFC, the SOFA, the HNFA, and

subject of this UFC. When the full text UFC is developed for this INACTIVE UFC 4-911-01N 16 January 2004 1-1 subject, applicable portions of these documents will be incorporated into the text. The designer is encouraged to access and review these documents as well as the references cited in Appendix A, MIL-HDBK 1130. 1. US Army Corps of Engineers USACE TM 5-610, Preventative Commander Maintenance for Facilities Engineering, USACE Publication Depot Buildings and Structures, 01 ATTN: CEIM-IM-PD November 1979 2803 52nd Avenue USACE TM 5-617, Facilities Hyattsville, MD 20781-1102 Engineering: Maintenance and Repair (301) 394-0081 fax: 0084 of Roofs, 30 January 1974 karl.abt@hq02.usace.army.mil http://www.usace.army.mil/inet/usace-docs/ USACE TM 5-620, Facilities Engineering: Maintenance and R

UFC 4-911-01N · para 5100.23 as of 2004-01-16 · official source ↗

c.navy.mil/safety/pub.htm. If any conflict occurs between this UFC and OPNAVINST 5100.23, the requirements of OPNAVINST 5100.23 take precedence. 1-2.3 FIRE PROTECTION. All DoD facilities must comply with UFC 3-600-01, Design: Fire Protection Engineering for Facilities. If any conflict occurs between this UFC and UFC 3-600-01, the requirements of UFC 3-600-01 take precedence. 1-2.4 ANTITERRORISM/FORCE PROTECTION. All DoD facilities must comply with UFC 4-010-01, Design: DoD Minimum Antiterrorism Standards for Buildings. If any conflict occurs between this UFC and UFC 4-010-01, the requirements of UFC 4-010-01 take precedence. 1-3 REFERENCES. The following Tri-Service publications have valuable information on the subject of this UFC. When the full text UFC is developed for this INACTIVE UFC

UFC 3-460-01 as of 2019-07-16 · official source ↗

-575-01, Lightning and Static Electricity Protection Systems UFC 3-580-01, Telecommunications Building Cabling Systems Planning and Design UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-022-03, Security Fences and Gates UFC 4-150-02, Dockside Utilities for Ship Service UFC 4-150-06, Military Harbors and Coastal Facilities UFC 4-152-01, Design: Piers and Wharves UFC 4-179-01, Design: Navy Firefighting School Facilities \2\ UFC 4-310-03, DoD Fuels Laboratory Standards /2/ UFC 4-832-01N, Design: Industrial and Oily Wastewater Control UFC 3-460-01 16 July 2019 Change 3, 08 June 2023 305 UFC 4-911-01N, O&M: Inactive Care and Closure of Shore Facilitie

AFSOCI 32-1084 · para 7.4.37 as of 2023-02-21 · open official PDF ↗

tant drains. Applicable criteria include UFC 3-401-01 for mechanical & UFC 3-410-01 for HVAC. Electrical Industrial equipment typically requires 240- and 480-volt, three-phase electrical current. Use commercial grade convenience receptacles and special power outlets. Consult X-ray and other NDI equipment specifications for their specific power requirements. Applicable criteria include UFC 3-501-01 for general electrical requirements, UFC 3-520-01 for interior electrical systems requirements, UFC 3-530-01 for interior and exterior lighting and controls requirements, UFC 3-550-01 for exterior power distribution systems requirements, UFC 3-560-01 for electrical safety and electrical O&M requirements, UFC 3-580-01 for building telecommunications requirements, and UFC 4-021-01 for mass notifica

UFC 4-141-10 as of 2022-09-22 · official source ↗

UFC 1-200-01 General Building Requirements UFC 2-000-05N Facility Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01 Architecture UFC 3-110-03 Roofing UFC 3-201-01 Civil Engineering UFC 3-220-01 Geotechnical Engineering UFC 3-250-01 Pavement Design for Roads and Parking Areas UFC 3-260-01 Airfield and Heliport Planning and Design UFC 3-260-04 Airfield and Heliport Marking UFC 3-301-01 Structural Engineering UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings UFC 4-141-10 22 September 2022 6 UFC 4-022-03 Security Fences and Gates UFC 3-401-01 Mechanical Engineering UFC 3-410-01 Heating, Ventilating and Air Conditioning Systems UFC 3-420-01 Plumbing Systems UFC 3-450-01 Noise and Vibration Control UFC 3-460-01 Design: Petroleum Fuel Facilities UFC 3-501-01 El

UFC 4-711-01 as of 2018-08-10 · official source ↗

/dod/ufc /3/ UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements (applicable to multi-family housing) UFC 2-100-01, Installation Master Planning UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-120-10, Interior Design UFC 3-210-10, Low Impact Development UFC 3-301-01, Structural Engineering \3\ /3/ UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-450-01, Noise and Vibration Control UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-570-01, Cathodic Protection UFC 3-600-01, Fire Protection Engineering For Facilities UFC 3-810-01N, Navy and Marine Corps Environmental Engineering for Facility Construction UFC 4-01

UFC 3-530-01 as of 2023-02-09 · official source ↗

.wbdg.org/ffc/dod/unified-facilities-criteria-ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-490-06, Elevators UFC 3-535-01, Visual Air Navigation Facilities UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-021-02, Electronic Security Systems UFC 4-022-01, Security Engineering: Entry Control Facilities/Access Control Points UFC 4-025-01, Security Engineering: Waterfront Security UFC 4-152-01, Design: Piers and Wharves UFC 4-510-01, Design: Military Medical Facilities UFC 4-740-02, Fitness Centers UFC 4-7

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.