Naval Facilities Engineering Command KATHLEEN I. FERGUSON, P.E. The Deputy Civil Engineer DCS/Installations & Logistics Department of the Air Force Dr. GET W. MOY, P.E. Director, Installations Requirements and Management Office of the Deputy Under Secretary of Defense (Installations and Environment) UFC 4-740-06 12 January 2006 Change 1, 21 March 2022 UNIFIED FACILITIES CRITERIA (UFC) NEW DOCUMENT SUMMARY Document: UFC 4-740-06, Youth Centers Superseding: There is no superseding data; this is a new, unified criteria document. Description: UFC 4-740-06 provides guidelines for evaluating, planning, programming, and designing Youth Centers. The information in this UFC applies to the design of all new construction projects, to include additions, alterations, and renovation projects in the cont
UFC 4-740-06 12 January 2006 Change 1, 21 March 2022 UNIFIED FACILITIES CRITERIA (UFC) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED YOUTH CENTERS UFC 4-740-06 12 January 2006 Change 1, 21 March 2022 UNIFIED FACILITIES CRITERIA (UFC) YOUTH CENTERS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location 1 21 March 2022 3-2, 3-5.3.2.1 changed Navy to preference for 1 story structure, same as Air Force. UFC 4-740-06 12 January 2006 Change 1, 21 March 2022 _
he recycled material content standards established by EPA. The list of products and their corresponding recycled content requirements are found at www.epa.gov/cpg/products. Listed products likely to be used in Youth Centers include building insulation, carpet and cushion, cement and concrete, latex paint, floor tiles, patio blocks, restroom dividers, and structural fiberboard. 3-9.2.2 The “Whole Building Design Guide” www.wbdg.org further explains the environmental issues related to building materials and provides technical guidance on green building material selection. UFC 4-740-06 12 January 2006 Change 1, 21 March 2022 33 3-9.3 DoD Energy Budget. Design of new facilities must ensure that building energy consumption does not exceed the DoD energy budget figures. UFC 4-740-06 12 January 2
recruitment and retention initiatives approved by the DoD Component. (b) Food-related expenses not paid by the USDA or DoD APFs. (c) Consumable supplies. c. Facility Requirements and Construction (1) Minimum prescribed construction standards: (a) For all Marine Corps, Navy, and Air Force CDC facility construction, the Unified Facilities Criteria (UFC) 4-740-14 (Reference (q)) apply. (b) For all Army CDC facility construction, the Army Standard for Child Development Centers (Reference (r)) apply. (c) When SAC is provided in youth facilities, UFC 4-740-06 (Reference (s)) and Service-specific exceptions to the UFC apply. (d) State and local construction standards may be used but are not required, except if the CDC facility is located on an area over which the United States has no legislative
recruitment and retention initiatives approved by the DoD Component. (b) Food-related expenses not paid by the USDA or DoD APFs. (c) Consumable supplies. c. Facility Requirements and Construction (1) Minimum prescribed construction standards: (a) For all Marine Corps, Navy, and Air Force CDC facility construction, the Unified Facilities Criteria (UFC) 4-740-14 (Reference (q)) apply. (b) For all Army CDC facility construction, the Army Standard for Child Development Centers (Reference (r)) apply. (c) When SAC is provided in youth facilities, UFC 4-740-06 (Reference (s)) and Service-specific exceptions to the UFC apply. (d) State and local construction standards may be used but are not required, except if the CDC facility is located on an area over which the United States has no legislative
Direct Digital Control for HVAC and Other Building Control Systems UFC 3-420-01, Plumbing Systems UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior and Exterior Lighting Systems UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-022-01, Security Engineering: Entry Control Facilities / Access Control Points UFC 4-023-10, Safe Havens UFC 4-026-01, Design to Resist Forced Entry UFC 4-740-06, Youth Centers UFC 4-730-01 20 March 2023 45 FC 4-740-14N, Navy and Marine Corps Child Development Centers UFC 4-740-15, Continuous Child Care Facilities C-2 NON-GOVERNMENT. AMERICAN INSTITUTE OF ARCHITECTS https://ww
ciation 101, “Life Safety Code,” current edition Public Law 113-291, Section 902, “The National Defense Authorization Act for Fiscal Year 2015,” December 19, 2014 Secretary of War Memorandum, “Department of War Secondary Titles,” October 10, 2025 Unified Facilities Criteria, UFC 3-600-01, “Fire Protection Engineering for Facilities,” November 28, 2016 Unified Facilities Criteria, UFC 4-740-06, “Youth Centers,” January 12, 2006 DoWI 6060.04, December 4, 2019 Change 1, June 23, 2026 REFERENCES 36 United States Code, Title 10, Sections 1785 and 1799 United States Code, Title 20 United States Code, Title 29, Section 794 (also known as “Section 504 of the Rehabilitation Act of 1973”) United States Code, Title 34, Section 20341
ciation 101, “Life Safety Code,” current edition Public Law 113-291, Section 902, “The National Defense Authorization Act for Fiscal Year 2015,” December 19, 2014 Secretary of War Memorandum, “Department of War Secondary Titles,” October 10, 2025 Unified Facilities Criteria, UFC 3-600-01, “Fire Protection Engineering for Facilities,” November 28, 2016 Unified Facilities Criteria, UFC 4-740-06, “Youth Centers,” January 12, 2006 DoWI 6060.04, December 4, 2019 Change 1, June 23, 2026 REFERENCES 36 United States Code, Title 10, Sections 1785 and 1799 United States Code, Title 20 United States Code, Title 29, Section 794 (also known as “Section 504 of the Rehabilitation Act of 1973”) United States Code, Title 34, Section 20341