ectives. UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 122 This Page Intentionally Left Blank UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 123 APPENDIX B \1\ SAMPLE INTERACTIVE SPREADSHEET. Figure B-1 illustrates a sample interactive spreadsheet completed for a hypothetical Navy fitness center. Figure B-1 Sample Interactive Worksheet for a Navy Fitness Center UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 124 UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 125 UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 126 UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 127 /1/ UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 128 This Page Intentionally Left Blank UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 129 APPENDIX C GLOSSARY C-1 ACRONYMS AND ABBREVIATIONS. ABA Ar
lding Design Guide UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 132 This Page Intentionally Left Blank UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 133 APPENDIX D REFERENCES DEPARTMENT OF DEFENSE (DOD) https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc UFC 1-200-01, DoD Building Code (General Building Requirements) UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 2-000-05N (P-80), Facility Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01, Architecture UFC 3-120-01, Design: Sign Standards UFC 3-120-10, Interior Design UFC 3-201-02, Landscape Architecture UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02, Direct Digital Control for HVAC and Other Building Control Systems UFC 3-420-01, Plumbing S
Engineering & Force Protection (HAF/A4C) United States Air Force Deputy Assistant Secretary of Defense (Facilities Investment and Management) Office of the Assistant Secretary of Defense (Energy, Installations, and Environment) UFC 4-740-02 3 February 2019 Change 1, 30 May 2019 UNIFIED FACILITIES CRITERIA (UFC) NEW DOCUMENT SUMMARY SHEET Document: UFC 4-740-02, Fitness Centers Superseding: FC 4-740-02F, Air Force Fitness Centers, dated 26 September 2006, and FC 4-740-02N, Navy and Marine Corps Fitness Centers, dated 1 April 2014. Description: This UFC provides criteria for planning and design of fitness centers for the combined DOD United States Armed Forces. Reasons for Document: This is a new Joint Service document. This document represents another step in the Joint Services’ effort to
Series - 131 Figure 74042-1. Community Recreation Center – Medium Size Facility CANCELED UFC 2-000-05 700 Series - 132 Figure 74042-2. Community Recreation Center – Large Size Facility 740 44 INDOOR PHYSICAL FITNESS CENTER (GYM) (SF) FAC: 7421 BFR Required: Y SECNAV-approved Fitness Standards and Metrics are available at http://www.navyfitness.org/fitness/fitness_standards_and_metrics/ Facility design criteria is available in UFC 4-740-02, “Fitness Centers” (https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc/ufc-4-740-02) CANCELED UFC 2-000-05 700 Series - 133 74044-1 GENERAL. Refer to the introductory material in 740-1, 740-2 and 740-3 found at the beginning of the 740 series category codes for general instructions regarding facility allowance planning procedures. Also, potentia
10-01, Design: Military Medical Facilities UFC 4-740-02, Fitness Centers UFC 4-740-14, Design: Child Development Centers FC 4-721-10N, Navy and Marine Corps, Unaccompanied Housing CANCELLED UFC 3-530-01 09 February 2023 Change 1, 15 December 2023 240 FC 4-740-14N, Navy and Marine Corps Child Development Centers WHOLE BUIDING DESIGN GUIDE RESOURCES Entry Control Facility/Access Control Point Lighting Analysis https://www.wbdg.org/FFC/DOD/UFC/ufc_3_530_01_ecf_acp_lighting_analysis.pdf CANCELLED
dings UFC 4-020-01, DoD Security Engineering Facilities Planning Manual CANCELLED UFC 3-600-01 8 August 2016 Change 6, 6 May 2021 161 UFC 4-021-01, Design and O&M: Mass Notification Systems UFC 4-150-02, Dockside Utilities for Ship Service UFC 4-151-10, General Criteria for Waterfront Construction UFC 4-152-01, Design: Piers and Wharves UFC 4-159-01N, Design: Hyperbaric Facilities UFC 4-211-01, Aircraft Maintenance Hangars UFC 4-211-02, Aircraft Corrosion Control and Paint Facilities UFC 4-213-10, Design: Graving Drydocks UFC 4-213-12, Drydocking Facilities Characteristics UFC 4-215-01, Armories and Arms Rooms UFC 4-310-03, DoD Fuels Laboratory Standards UFC 4-510-01, Design: Medical Military Facilities UFC 4-740-06, Youth Centers UFC 4-740-14, Design: Child Development Centers UNITED STAT
h Performance and Sustainable Building Requirements UFC 3-120-01, Design: Sign Standards UFC 3-201-01, Civil Engineering UFC 3-210-10, Low Impact Development UFC 3-301-01, Structural Engineering UFC 3-420-01, Plumbing Systems UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 4-010-01, DoD Minimum Anti-Terrorism Standard for Buildings UFC 4-010-06, Cybersecurity of Facility-related Control Systems UFC 4-022-02, Selection and Application of Vehicle Barriers UFC 4-022-03, Security Fences and Gates UFC 4-740-14, Design: Child Development Centers FC 4-740-14N, Navy and Marine Corps Child Development Centers UFC 4-740-16, Design: Military Recreation Centers UFC 4-750-02N, Design: Outdoor Sports and Recreational Facilities UFC 4-750-07, Recreational Aquatics Facilities U.S. As
her areas in the facility, coordinate with the architect to locate these spaces in the interior to prevent CANCELLED UFC 3-410-01 28 July 2025 Change 1, 23 January 2026 11 negative pressure induced infiltration of outdoor air into exterior wall cavities. Medical labs must meet the requirements of UFC 4-510-01. 2-5.8 \1\ Exercise-Related Spaces. /1/ \1\ For any facility type containing exercise-related space types addressed in UFC 4- 740-02, HVAC design for those spaces must comply both with this document and UFC 4-740-02. /1/ 2-5.9 Aircraft Maintenance Shops. Provide air conditioning for those functional areas where required for quality control of equipment, material, and task. Localized or spot air conditioning is allowed at individual workstations. 2-5.10 Aircraft Fire and Rescue and Fir
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.