Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

Governing guidance

Showing the controlling passages directly. (daily question limit reached — showing passages)

UFC 4-730-10 as of 2019-05-08 · official source ↗

g/. Refer to UFC 1-200-01, DoD Building Code (General Building Requirements), for implementation of new issuances on projects. AUTHORIZED BY: LARRY D. McCALLISTER, PhD, P.E., PMP, SES JOSEPH E. GOTT, P.E. Chief Engineer Chief, Engineering and Construction US Army Corps of Engineers Naval Facilities Engineering Command NANCY J. BALKUS, P.E., SES MICHAEL McANDREW Deputy Director of Civil Engineers DCS/Logistics, Engineering & Force Protection (HAF/A4C) HQ United States Air Force Deputy Assistant Secretary of Defense (Facilities Management) Office of the Assistant Secretary of Defense (Sustainment) UFC 4-730-10 8 May 2019 Change 1, 11 June 2021 UNIFIED FACILITIES CRITERIA (UFC) NEW DOCUMENT SUMMARY SHEET Document: UFC 4-730-10, Fire Stations Superseding: UFC 4-730-10, Fire Stations, dated 15

UFC 4-730-10 · para 1926.502 as of 2019-05-08 · official source ↗

required area around the vehicle footprint. Paragraph 2-3.1.1 gives the standard truck sizes and their relative footprints. The diagrams in Figures B-1 through B-4 illustrate the required space around each vehicle size class. Each diagram has three possible configurations: a truck parked between two walls, a truck parked between a wall and another truck, and a truck parked between two other trucks. This is due to the different set-off distances for a wall versus another vehicle. UFC 4-730-10 8 May 2019 Change 1, 11 June 2021 78 Figure B-1 Large Vehicle Class UFC 4-730-10 8 May 2019 Change 1, 11 June 2021 79 Figure B-2 Medium Vehicle Class UFC 4-730-10 8 May 2019 Change 1, 11 June 2021 80 Figure B-3 Large ARFF (Wide) Vehicle Class UFC 4-730-10 8 May 2019 Change 1, 11 June 2021 81 Figure B-4

UFC 4-730-10 as of 2019-05-08 · official source ↗

UFC 4-730-10, Fire Stations Superseding: UFC 4-730-10, Fire Stations, dated 15 June 2006, and FC 4-730-10N, Navy and Marine Corps Fire Stations, dated 1 December 2013. Description: This UFC provides criteria for planning and design of fire stations. This UFC includes guidance for Air Force, Army, Marine Corps, and Navy fire stations. Reasons for Document: This is a new joint-Service document. This new document represents another step in the joint-Services’ effort to bring uniformity to the planning, design, and construction of military facilities. This UFC was developed to provide design requirements to accomplish the following: • Assist planners in understanding facility requirements to ensure accurate space program budgets. • Provide architects, engineers, and construction surveillance

FC 2-000-05N as of 2026-02-11 · official source ↗

ria for these facilities are currently available. CANCELED UFC 2-000-05 700 Series - 49 730 COMMUNITY FACILITIES – PERSONNEL SUPPORT AND SERVICES 730 10 FIRE STATION (SF) FAC: 7311 BFR Required: Y Refer to https://www.wbdg.org/ffc/dod/unified-facilities-space-program- sustainability-spreadsheets for the “Fire Stations Space Program” spreadsheet Refer to UFC 4-730-10 “Fire Stations” for design criteria. 73010-1 DEFINITION. This space criteria applies to Installation fire station facilities which provide fire protection for structures, fight brushfires, and support fire prevention education and training. 73010-1.1 When the fire station function is part of a consolidated operations facility (fire/police/safety), this CCN is applicable only to the fire station functions and the planner must co

UFC 3-501-01 as of 2024-11-27 · official source ↗

722 10 Detached dining facilities, enlisted men 30-35 45-60 723 20 Latrine, detached 75-80 20-25 723 30 Laundry, detached 30-35 20-25 723 40 Garage, detached 40-50 2-4 724 11 UOPH, W-1/0-2 40-50 20-25 724 12 UOPH, 0-3 and above 40-50 20-25 724 22 Civilian quarters, GS-7/PLS 40-50 20-25 724 30 Dining facility (attached) commissioned personnel 35-40 30-40 730 10 Fire station 25-35 13-17 730 15 Confinement facility 60-65 33-38 730 20 Police station 48-53 20-25 CANCELLED UFC 3-501-01 27 November 2024 56 Navy Code Description Demand Factor (%) Load Factor (%) 730 25 Gate/sentry house 70-75 28-33 730 30 Bakery 30-35 45-60 730 35 Enlisted personnel locker room 75-80 18-23 730 40 Laundry/dry cleaning plant 30-35 20-25 730 45 Dependent school – nursery school 75-80 10-15 730 50 Dependent school – k

UFC 3-540-01 as of 2014-08-01 · official source ↗

ilities( UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 31 4-730-04AN, Military Police Facilities (INACTIVE) 4-730-10, Fire Stations 4-740-02, Fitness Centers UNDERWRITER’S LABORATORIES https://standardscatalog.ul.com/ 1008, Transfer Switch Equipment /3/ UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 32 This Page Intentionally Left Blank UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 33 APPENDIX B EXAMPLES OF SYSTEM CONFIGURATIONS B-1 INTRODUCTION. Appendix B provides examples and simple depictions of different configurations. B-2 SINGLE GENERATOR SYSTEM CONFIGURATIONS. B-2.1 Single Engine Generator Supply to Essential Loads. If the facility has a permanently installed emergency power source, provide a separate panel to supply only the loads requiring emergency power. Thi

AFRCH 32-1001 · para 6.12 as of 2023-10-19 · open official PDF ↗

agement (FAC 6100; CATCODE 610-913): The Emergency Management function is normally part of, and co-located with, the Civil Engineer Prime BEEF Squadron. Table 6.6. Emergency Management. DESCRIPTION SCOPE (NSF) Host Tenant Flight Chief / Commander 100 100 Emergency Management 36 FT + 20 PT 36 FT + 20 PT Training Room 700 600 Breakroom 150 CBRNE Cell (control center) 200 Storage — Mobility 5 EA 5 EA Storage — UTC Equipment 300 Storage — Secure 100 50 Response Vehicle Staging (Covered Vehicle Storage) 600 0 6.12. Fire Station (BOS Firefighter Facility) (FAC 7311; CATCODE 730-142): Refer to UFC 4-730-10, Fire Stations, for mission specific facility information, regarding evaluating, planning, programming, and designing fire stations. 6.13. Reserve Firefighter Training Facility (FAC 1714; CATCO

ly CSP Rates – Army (Continued) Effective October 1, 2002 Pay Grade Cumulative Years of Sea Duty Over 9 Over 10 Over 11 Over 12 Over 13 Over 14 Over 16 Over 18 Over 20 O-6 280 290 300 310 310 325 340 355 380 O-5 250 260 265 265 265 285 300 315 340 O-4 220 225 225 240 240 270 280 290 300 O-3 215 225 225 240 240 260 270 280 290 O-2 215 225 225 240 240 250 260 270 280 O-1 215 225 225 240 240 250 260 270 280 W-5 534 590 625 660 660 730 730 730 730 W-4 534 590 625 660 660 730 730 730 730 W-3 534 590 625 660 660 695 695 695 695 W-2 534 576 576 625 625 625 625 625 625 W-1 520 555 555 555 555 555 555 555 555 E-9 490 490 503 516 555 588 620 646 646 E-8 490 490 503 516 555 588 620 646 646 E-7 490 490 503 516 555 588 620 620 620 E-6 445 445 445 464 484 503 523 555 555 E-5 425 425 425 425 425 425 425

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.