Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

UFC 4-730-04AN is INACTIVE [UFC 4-730-04AN foreword]. It is a Unified Facilities Criteria document on Military Police Facilities that superseded DG 1110-3-146 (dated December 1979) and was current as of 1 March 2005 [UFC 4-730-04AN cover page, Record of Changes]. The document was prepared by the U.S. Army Corps of Engineers with the Naval Facilities Engineering Command and Air Force Civil Engineer Support Agency [UFC 4-730-04AN signature block].

The publication applies to Military Departments, Defense Agencies, and DoD Field Activities in accordance with the UFC system prescribed by MIL-STD 3007 [UFC 4-730-04AN foreword]. However, since the document is marked inactive, current projects should reference active UFC publications for military police facility design criteria.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
NFPA standards (cited by reference)
NFPA 780 Installation of Lightning Protection Systems — cited by AFSOCI 32-1084 (sections 8.1.1, 8) · read at NFPA free access ↗
NFPA 33 — cited by AFSOCI 32-1084 · read at NFPA free access ↗

NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.

Show the 8 source passage(s) this answer is built from

UFC 4-730-04AN 01 March 2005 UNIFIED FACILITIES CRITERIA (UFC) MILITARY POLICE FACILITIES APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED INACTIVE UFC 4-730-04AN 01 March 2005 1 UNIFIED FACILITIES CRITERIA (UFC) MILITARY POLICE FACILITIES Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS (Preparing Activity) NAVAL FACILITIES ENGINEERING COMMAND AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location This UFC supersedes DG 1110-3-146, dated December 1979. The format of this UFC does not conform to UFC 1-300-01; however, the format will be adjusted to conform at t

__________________________ DONALD L. BASHAM, P.E. Chief, Engineering and Construction U.S. Army Corps of Engineers ______________________________________ DR. JAMES W WRIGHT, P.E. Chief Engineer Naval Facilities Engineering Command ______________________________________ KATHLEEN I. FERGUSON, P.E. The Deputy Civil Engineer DCS/Installations & Logistics Department of the Air Force ______________________________________ Dr. GET W. MOY, P.E. Director, Installations Requirements and Management Office of the Deputy Under Secretary of Defense (Installations and Environment) INACTIVE UFC 4-730-04AN 1 MARCH 2005 Foreword - Continued 1 GENERAL BUILDING REQUIREMENTS. Design all DoD facilities to comply with UFC 1-200-01, Design: General Building Requirements. If any conflict occurs between this UFC an

ot conform to UFC 1-300-01; however, the format will be adjusted to conform at the next revision. The body of this UFC is the previous DG 1110-3-146, dated December 1979. INACTIVE UFC 4-730-04AN 01 March 2005 2 FOREWORD \1\ The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some

UFC 3-540-01 as of 2014-08-01 · official source ↗

ilities( UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 31 4-730-04AN, Military Police Facilities (INACTIVE) 4-730-10, Fire Stations 4-740-02, Fitness Centers UNDERWRITER’S LABORATORIES https://standardscatalog.ul.com/ 1008, Transfer Switch Equipment /3/ UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 32 This Page Intentionally Left Blank UFC 3-540-01 1 August 2014 Change 4, 16 January 2026 33 APPENDIX B EXAMPLES OF SYSTEM CONFIGURATIONS B-1 INTRODUCTION. Appendix B provides examples and simple depictions of different configurations. B-2 SINGLE GENERATOR SYSTEM CONFIGURATIONS. B-2.1 Single Engine Generator Supply to Essential Loads. If the facility has a permanently installed emergency power source, provide a separate panel to supply only the loads requiring emergency power. Thi

AFSOCI 32-1084 · para 7.4.37 as of 2023-02-21 · open official PDF ↗

tant drains. Applicable criteria include UFC 3-401-01 for mechanical & UFC 3-410-01 for HVAC. Electrical Industrial equipment typically requires 240- and 480-volt, three-phase electrical current. Use commercial grade convenience receptacles and special power outlets. Consult X-ray and other NDI equipment specifications for their specific power requirements. Applicable criteria include UFC 3-501-01 for general electrical requirements, UFC 3-520-01 for interior electrical systems requirements, UFC 3-530-01 for interior and exterior lighting and controls requirements, UFC 3-550-01 for exterior power distribution systems requirements, UFC 3-560-01 for electrical safety and electrical O&M requirements, UFC 3-580-01 for building telecommunications requirements, and UFC 4-021-01 for mass notifica

UFC 4-141-10 as of 2022-09-22 · official source ↗

UFC 1-200-01 General Building Requirements UFC 2-000-05N Facility Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01 Architecture UFC 3-110-03 Roofing UFC 3-201-01 Civil Engineering UFC 3-220-01 Geotechnical Engineering UFC 3-250-01 Pavement Design for Roads and Parking Areas UFC 3-260-01 Airfield and Heliport Planning and Design UFC 3-260-04 Airfield and Heliport Marking UFC 3-301-01 Structural Engineering UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings UFC 4-141-10 22 September 2022 6 UFC 4-022-03 Security Fences and Gates UFC 3-401-01 Mechanical Engineering UFC 3-410-01 Heating, Ventilating and Air Conditioning Systems UFC 3-420-01 Plumbing Systems UFC 3-450-01 Noise and Vibration Control UFC 3-460-01 Design: Petroleum Fuel Facilities UFC 3-501-01 El

UFC 4-711-01 as of 2018-08-10 · official source ↗

/dod/ufc /3/ UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements (applicable to multi-family housing) UFC 2-100-01, Installation Master Planning UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-120-10, Interior Design UFC 3-210-10, Low Impact Development UFC 3-301-01, Structural Engineering \3\ /3/ UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-450-01, Noise and Vibration Control UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-570-01, Cathodic Protection UFC 3-600-01, Fire Protection Engineering For Facilities UFC 3-810-01N, Navy and Marine Corps Environmental Engineering for Facility Construction UFC 4-01

UFC 3-530-01 as of 2023-02-09 · official source ↗

.wbdg.org/ffc/dod/unified-facilities-criteria-ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-490-06, Elevators UFC 3-535-01, Visual Air Navigation Facilities UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-021-02, Electronic Security Systems UFC 4-022-01, Security Engineering: Entry Control Facilities/Access Control Points UFC 4-025-01, Security Engineering: Waterfront Security UFC 4-152-01, Design: Piers and Wharves UFC 4-510-01, Design: Military Medical Facilities UFC 4-740-02, Fitness Centers UFC 4-7

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.