Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.
Showing the controlling passages directly. (daily question limit reached — showing passages)
01, DoD Building Code (General Building Requirements), for implementation of new issuances on projects. AUTHORIZED BY: LARRY D. McCALLISTER, PhD, PE, PMP, SES JOSEPH E. GOTT, P.E. Chief, Engineering and Construction Chief Engineer Directorate of Civil Works U.S. Army Corps of Engineers Naval Facilities Engineering Command NANCY J. BALKUS, PE, SES, DAF Deputy Director of Civil Engineers DCS/Logistics, Engineering & Force Protection MICHAEL MCANDREW Deputy Assistant Secretary of Defense (Facilities Investment and Management) Office of the Assistant Secretary of Defense (Energy, Installations, and Environment) UFC 4-711-01 10 August 2018 Change 4, 21 April 2026 UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 4-711-01, Superseding: 2006 version of UFC 4-711-01, DESIGN: F
EET Document: UFC 4-711-01, Superseding: 2006 version of UFC 4-711-01, DESIGN: FAMILY HOUSING Description: This is a Joint-Service document that supersedes and updates the 2006 version of the same UFC. Reasons for Document: The UFC 4-711-01, FAMILY HOUSING represents another step in the joint Services effort to bring uniformity to the planning, design and construction of military Family Housing. This revision updates the 2006 UFC in accordance with the following: • Alignment with the latest model codes, standards, and practices governing quality residential construction. • Update housing unit design to better reflect off-post market equivalents and privatized housing. • Elimination of two bedroom units. • Incorporation of minimum areas for critical dwelling unit spaces. • Requirement for 2
with water tanks. UFC 4-711-01 10 August 2018 Change 4, 21 April 2026 41 5-5 SANITARY SEWER. For IBC buildings, comply with UFC 3-420-01, Plumbing Systems, and the IPC which it augments. For IRC buildings, comply with the IRC. For all housing types, locate vent stacks to rear of housing units, and consolidate to limit the number of roof penetrations. Provide drains for air-conditioning condensation, humidifier overflow, and water heater and relief valves. Drains \3\ must /3/ discharge to the exterior. 5-6 GAS. Comply with NFPA 54 National Fuel Gas Code and NFPA 58 Liquefied Petroleum Gas Code as applicable. UFC 4-711-01 10 August 2018 Change 4, 21 April 2026 42 This Page Intentionally Left Blank UFC 4-711-01 10 August 2018 Change 4, 21 April 2026 43 CHAPTER 6 FIRE AND LIFE SAFETY 6-1 FIRE
able to the occupants. 714 10 DETACHED GARAGES (SF) FAC: 7141 BFR Required: N Design Criteria: See UFC 4-711-01 “Family Housing” 71410-1 REQUIREMENTS. Detached garages are planned on the basis of one per living unit and a space allowance of one vehicle per garage at those locations subject to temperatures of -10º Fahrenheit and below or where extreme winds, salt air, or sandstorms require garages. See UFC 4-711-01 “Family Housing” for detailed guidance. 714 20 DETACHED CARPORTS (SF) FAC: 7141 BFR Required: N Design Criteria: See UFC 4-711-01 “Family Housing” 71420-1 REQUIREMENTS. Detached carports are also provided on the basis of one per living unit and a space allowance of one vehicle per carport. See UFC 4-711-01 “Family Housing” for detailed guidance. 714 30 FAMILY HOUSING - OTHER DETA
s programmed to restore damaged or destroyed units. AFI32-6000 18 MARCH 2020 167 11.18.2.6.1. SAF/IEI approves and provides prior notification to Congress for projects that exceed either 75 percent of the replacement costs, or $100,000 per unit. 11.18.2.6.2. The approving authority, as delegated in Table 11.1, determines the need for repair or replacement due to damage caused by unforeseen events and not from long-term deterioration. See Table 11.1 for approval levels and Attachment 15.20 for sample DD Form 1391. 11.19. Family Housing Design Standards. Ensure FH designs follow statutory limitations, all applicable UFCs including UFC 4-711-01 Family Housing, and concepts in the housing community plan and the Air Force Family Housing Guide, regardless of the funding source. (T-1) AFCEC/CI an
4-010-05, SCIF/SAPF Planning, Design, and Construction /3/ UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-021-01, Design and O&M: Mass Notification Systems UFC 4-510-01, Design: Military Medical Facilities UFC 4-711-01, Family Housing FC 4-721-10N, Navy and Marine Corps Unaccompanied Housing UNITED STATES ACCESS BOARD \2\ Architectural Barriers Act /2/ (ABA) Standards https://www.access-board.gov/files/aba/ABAstandards.pdf UNITED STATES AIR FORCE https://www.e-publishing.af.mil DESR6055.09_AFMAN91-201, Explosives Safety Standards DAFMAN 91-203, Air Force Occupational Safety, Fire and Health Standards UNITED STATES ARMY https://armypubs.army.mil/ DA PAM 385-64, Ammunition and Explosives Safety Standards CANCELLED UFC 1-200-01 01 September 2022 Change 4, 17 December 20
, child development centers, and other facilities. 5.3.1.10. Current criteria in the UFC includes 4-740-14, Child Development Centers; UFC 4-711-01, Family Housing, and UFC 4-030-01, Sustainable Development. 5.3.1.11. Installations determined by the USAF School of Aerospace Medicine (USAFSAM) to be low-risk in accordance with the Bioenvironmental Engineer’s Guidebook for Radon Management are exempt from program requirements. 5.3.2. Uncontrolled Exposures Resulting from Radiological Incidents and Accidents. Members of the public that are under the protection of an installation commander shall be protected during emergency situations from exposure to radiation to the greatest extent possible. Specific protective measures that can be implemented are listed in Attachment 6. The decision to inv
Family Housing Construction Air Force/Space Force. Appropriation Fund Code Description 576/00740 3X Family Housing Construction, Air Force 7.1.2.1. Project 711 New Construction (BA 01). This project provides for: 7.1.2.1.1. Erecting, installing, assembling, relocating, constructing, or replacing family dwelling units. 7.1.2.1.2. Related land acquisition, site preparation, excavating, filling, landscaping, demolition, environmental remediation, or improving sites relating to work in Project 711. 7.1.2.1.3. Initial outfitting of major equipment to include appliances such as kitchen ranges, refrigerators, and dishwashers; provide plumbing and electrical connections for use of washing machines and clothes dryers. 7.1.2.1.4. Supervision and inspection of construction. 7.1.2.1.5. Construction o
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.