highly dependent on the mixture of enclosed and open spaces. As mentioned previously, facilities with more open office workstations and collaboration areas will require a higher circulation factor than a facility with more enclosed offices and conference rooms. The following excerpts from a GSA study “Circulation: Defining and Planning” illustrate this relationship. UFC 4-610-01 05 January 2021 Change 1, 30 April 2021 84 Figure A-1 Circulation Case Study 0/100 Figure A-2 Circulation Case Study 33/67 UFC 4-610-01 05 January 2021 Change 1, 30 April 2021 85 Figure A-3 Circulation Case Study 80/20 Figure A-4 Circulation Case Study 100/0 A-2 SPACE PLANNING AND OFFICE DESIGN. UFC 4-610-01 05 January 2021 Change 1, 30 April 2021 86 The basic building blocks of an administrative facility are the w
CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 4-610-01, Administrative Facilities Superseding: UFC 4-610-01, Administration Facilities, dated 6 May 2008, with Changes 1-2, dated 21 May 2014 Description: This UFC provides planning and design criteria for Administrative Facilities. It outlines methods of space allocation and typical functional spaces to accommodate the executive and staff functions of an installation or particular organization. Reasons for Document: • To provide a unified approach to effectively planning, allocating space and designing, administrative facilities with updated methodologies and technologies, and incorporate the integrated design process. Impact: The following direct benefits will result from publication, revision and change of the UFC. • More consistency
wbdg.org/ffc/dod. Refer to UFC 1-200-01, DoD Building Code, for implementation of new issuances on projects. AUTHORIZED BY: CHRISTINE T. ALTENDORF, PhD, P.E., SES R. DAVID CURFMAN, P.E., SES Chief Engineer Chief, Engineering and Construction Naval Facilities Engineering Systems Command U.S. Army Corps of Engineers NANCY J. BALKUS, P.E., SES Deputy Director of Civil Engineers DCS/Logistics, Engineering & Force Protection (HAF/A4C) HQ United States Air Force MICHAEL McANDREW Deputy Assistant Secretary of Defense (Construction) and Acting Deputy Assistant Secretary of Defense (Housing) Office of the Assistant Secretary of Defense (Sustainment UFC 4-610-01 05 January 2021 Change 1, 30 April 2021 UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 4-610-01, Administrative Fac
facilities at locations designated as austere. The flexibility should be allowed to ensure the criteria are appropriate for individual austere locations. Austere facilities should be built with the least total ownership costs (TOC) possible, including purchase, maintenance and use of consistently available alternative local goods. APPLICABILITY This Appendix should be used for proper space planning of all facilities that are designated as austere during project programming by CNIC and OPNAV. CANCELED UFC 2-000-05N APPENDIX F 12 June 2022 2 610 50 AUSTERE ADMINISTRATIVE FACILITY (SF) For austere administrative facilities design criteria, refer to UFC 4-610-01 Appendix C, located here: https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc/ufc-4-610-01 61050-1 DEFINITION. Austere admi
01-01, Electrical Engineering UFC 3-600-01, Fire Protection Engineering for Facilities UFC 3-701-01, DoD Facilities Pricing Guide UFC 3-730-01, Programming Cost Estimates for Military Construction UFC 3-740-05, Construction Cost Estimating UFC 3-810-01N, Navy and Marine Corps Environmental Engineering for Facility Construction UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-010-05, SCIF/ SAPF Planning, Design, and Construction UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-023-03, Design of Buildings to Resist Progressive Collapse UFC 4-510-01, Design: Medical Military Facilities UFC 4-610-01, Administrative Facilities UFC 4-722-01, Design: Dining Facilities FC 1-300-09N 17 May 2024 Change 1, 17 April 2025 187 UFC 4-740-02, Fitness Centers UNIFI
ineering for Facilities UFC 4-010-05, Sensitive Compartmented Information Facilities Planning, Design, and Construction UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-021-02, Electronic Security Systems UFC 4-440-01, Design: Warehouses and Storage Facilities, currently in Draft and anticipated to be published January 2014. UFC 4-610-01, Administrative Facilities UFC 4-740-20, Libraries UFGS 23 09 23.13 20, BACnet Direct Digital Control Systems for HVAC DEPARTMENT OF THE NAVY OPNAVINST 5450.342, Mission, Functions, and Tasks of the Naval History and Heritage Command OPNAVINST 5530.13C Physical Security Instruction for Conventional Arms, Ammunition, and Explosives (AA&E) SECNAVINST 4000.35A, Cultural Resources Program SECNAVINST M-5510.36, Information Security Progra
) (1.96) 71 24.0 x 18.0 x 18.0 24.5 x 18.5 x 18.5 4.853 5.00 8115-01-163-9189 (610 x 457 x 457) (622 x 470 x 470) (0.137) (2.27) 72 24.0 x 20.0 x 16.0 24.5 x 20.5 x 16.5 4.796 5.30 8115-00-417-9236 (610 x 508 x 406) (622 x 521 x 419) (0.136) (2.40) 73 24.0 x 24.0 x 10.0 24.5 x 24.5 x 10.5 3.647 5.45 8115-00-428-4124 (610 x 610 x 254) (622 x 622 x 267) (0.103) (2.47) 74 24.0 x 24.0 x 12.0 24.5 x 24.5 x 12.5 4.342 5.75 8115-00-174-2354 (610 x 610 x 305) (622 x 622 x 318) (0.123) (2.61) 75 24.0 x 24.0 x 16.0 24.5 x 24.5 x 16.5 5.732 6.05 8115-01-119-2523 (610 x 610 x 406) (622 x 622 x 419) (0.162) (2.74) 76 24.0 x 24.0 x 20.0 24.5 x 24.5 x 20.5 7.121 6.70 8115-01-166-6451 (610 x 610 x 508) (622 x 622 x 521) (0.202) (3.04) 77 24.0 x 24.0 x 24.0 24.5 x 24.5 x 24.5 8.511 7.62 8115-00-417-9416 (6
Six inches wide solid white aircraft safety perimeter line following clearances per Table 2-1: Minimum Aircraft Maintenance Bay Clearances. 4. \2\ Aircraft position centerline & nose gear stop; 6" wide stripe; color – yellow or white to match marking from outside the hangar to inside the hangar. May not be required at multi-aircraft position hangars. Coordinate with users. /2/ 5. Grounding receptacle; paint per UFC 3-575-01, Figure 2-3. 6. Safety eyewash/shower; color - green; provide 2 ft. (610 mm) clearance from safety equipment. Slope to drain, if provided. 7. Fire Extinguishers (if provided); color - red. Provide 2 ft. (610 mm) clearance from extinguishers. UFC 4-211-01 13 April 2017 Change 3, April 20, 2021 185 STRUCTURAL Aircraft Maintenance Bay - Slab on Ground Loading Design Navy/U