Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

UFC 4-216-02 is inactive as a design criteria publication [UFC 3-410-04].

However, it remains referenced as the applicable design criteria for maintenance facilities for ammunition, explosives, and toxics. When developing space requirements for such facilities, designers must consult UFC 4-216-02 [FC 2-000-05N]. Additionally, all DoD facilities must comply with UFC 3-600-01 (Fire Protection) and UFC 4-010-01 (Antiterrorism/Force Protection); if conflicts arise between UFC 4-216-02 and those standards, the fire protection and force protection requirements take precedence [UFC 4-216-02 para 1-2.3, 1-2.4].

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
NFPA standards (cited by reference)
NFPA 99 — cited by CFETP 4A1X1 (sections 6, 10.2.3.6, 2, 14) · read at NFPA free access ↗
NFPA 55 — cited by CFETP 4A1X1 · read at NFPA free access ↗

NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.

Show the 8 source passage(s) this answer is built from
UFC 4-216-02 as of 2004-01-16 · official source ↗

CTIVE UFC 4-216-02 16 January 2004 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.) Therefore, the acquisition team must ensure compliance with the more stringent of the UFC, the SOFA, the HNFA, and the BIA, as

UFC 4-216-02 · para 5100.23 as of 2004-01-16 · official source ↗

AVINST 5100.23, the requirements of OPNAVINST 5100.23 take precedence. 1-2.3 FIRE PROTECTION. All DoD facilities must comply with UFC 3-600-01, Design: Fire Protection Engineering for Facilities. If any conflict occurs between this UFC and UFC 3-600-01, the requirements of UFC 3-600-01 take precedence. 1-2.4 ANTITERRORISM/FORCE PROTECTION. All DoD facilities must comply with UFC 4-010-01, Design: DoD Minimum Antiterrorism Standards for Buildings. If any conflict occurs between this UFC and UFC 4-010-01, the requirements of UFC 4-010-01 take precedence. 1-3 REFERENCES. The following Tri-Service publications have valuable information on the subject of this UFC. When the full text UFC is developed for this subject, applicable portions of these documents will be incorporated into the text. The

UFC 3-410-04 as of 2017-12-13 · official source ↗

-01, General Building Requirements UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-450-01, Noise and Vibration Control UFC 3-520-05, Stationary and Mission Batteries UFC 3-600-01, Fire Protection Engineering For Facilities UFC 4-211-02, Aircraft Corrosion Control and Paint Facilities UFC 4-216-02, Design: Maintenance Facilities for Ammunition, Explosives, and Toxins (Inactive) U.S. ENVIRONMENTAL PROTECTION AGENCY http://www.epa.gov EPA-560-OPTS-86-001, A Guide to Respiratory Protection for the Asbestos Abatement Industry DEPARTMENT OF LABOR 29 CFR 1910.94(a), Abrasive Blasting UFC 3-410-04 13 December 2017 77 NATIONAL ELECTRICAL MANUFACTURER’

FC 2-000-05N as of 2026-02-11 · official source ↗

rmine the space requirements. 21560-2 For other field maintenance functions, see Category Codes 214 53, 217 30, and 218 80. 216 MAINTENANCE AMMUNITION, EXPLOSIVES & TOXICS 216-1 DEFINITION. This group includes facilities for maintenance of ammunition, rockets, bombs, mines, grenades, torpedoes, depth charges, demolition materials, pyrotechnics, missile fuels, and related chemicals. OPNAV Instruction 8000.16 series provides maintenance policies, procedures, and responsibilities for the conduct of the Naval Ordnance Maintenance Management Program. Siting criteria and guidance on standard operating procedures for these facilities can be found in NAVSEA OP-5 Vol. 1. Consult the design criteria, UFC 4-216-02, when developing space requirements. 216 05 CHANGE/RELIEF HOUSE (SF) FAC: 2162 BFR Requ

UFM 3-260-03 as of 2026-02-23 · official source ↗

Heliport Design, https://armypubs.army.mil/ProductMaps/PubForm/Details.aspx?PUB_ID=106072 TM 5-803-4, Planning of Army Aviation Facilities TSC Report 13-2, Aircraft Characteristics for Airfield Pavement Design and Evaluation - Air Force and Army Aircraft, https://transportation.erdc.dren.mil/tsmcx/criteria.aspx TSC Report 13-3, Aircraft Characteristics for Airfield Pavement Design and Evaluation - Commercial Aircraft, https://transportation.erdc.dren.mil/tsmcx/criteria.aspx UFM 3-260-03 23 February 2026 216 AIR FORCE AFI 32-1041, Pavement Evaluation Program, https://www.e-publishing.af.mil/ DEPARTMENT OF DEFENSE https://www.wbdg.org/dod/ufc UFS 3-250-11, Soil Stabilization and Modification for Pavements UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-260-02, Pavement Design

CFETP 4A1X1 · para 4.3 as of 2023-01-26 · open official PDF ↗

dical Logistics Order Management; DHA PM 6040.06, Medical Logistics (MEDLOG) Medical Gas Services; DHA PM 6430.03, Medical Logistics Materiel Quality Procedures; DHA TM 6430.02, Volume 4, DMLSS-Volume 4, Inventory Management; DHA TM 6430.02, Volume 5, DMLSS-Volume 5, Inventory and Quality Control; DHA TM 6430.02, Volume 7, DMLSS- Volume 7, Equipment Management and Equipment Maintenance 4.1. Identify principles of inventory management B 4.2. Perform inventory procedures 2b 4.3. Perform controlled item inventory procedures 2b 5.OPERATIONAL MEDICAL LOGISTICS TR: AFMAN 41-209, Medical Logistics Support AFMAN 41-216, Defense Medical Logistics Standard Support (DMLSS) Users Manual; DHA AI 4000.01, Property Accountability and Management of General Equipment (GE); DHA AI 6430.09, Defense Health Ag

UFC 4-179-02 as of 2020-03-05 · official source ↗

E, HEDP, TP, Practice, Smoke, Illumination (M381, M384, M385, M386, M406, M407A1, M430, M433, M441, M661, M662, M583A1, M992, M713, M715, M716, M781, M918) 708 (216)3 Grenade Launcher, 40mm (M203, M320) BA06 40mm Ctg Non-Lethal Sponge (M1006) 328 (100) Grenade Launcher, 40mm (M203, M320) B534 40mm Ctg, Multi Projectile (M576) 246 (75) Machine Gun, 40mm Linked (MK19) BA30, B542, B576, B584, BA32, BA21, BA12 Ctg 40mm Linked HEDP, TP, Practice, Mixed (M430/M918/M385/M385A1/M918 & M385/ MK281) 1565 (477)3 Light Anti-armor Weapon (LAW), 35mm Sub-Caliber (M72-Series LAW) H708 Rocket, 35mm, Practice (M73) 666 (203)3 UFC 4-179-02 5 March 2020 Change 1, 13 March 2025 12 Weapon/Caliber DOD Identification Code (DODIC) Ammunition Nomenclature Minimum VDZ Height5 Feet (Meters) LAW, 66mm RKT HEAT (M72-S

CFETP 1N8X1 · para 2.4 as of 2025-12-19 · open official PDF ↗

-13 2.3.1.3 Naval Systems TR: AFTTP 3-1 All A Volumes 2.3.1.4 Space Threat Systems TR: AFTTP 3-1 A All Volumes 2.3.1.5 Theater Ballistic Missile (TBM) A systems TR: AFTTP 3-1 All Volumes 2.3.1.6 Asymmetric Threats TR: AFTTP 3-4.2 ATG, Asymmetry and U.S. Military Strategy, Rethinking Asymmetric A Threats (both found at www.strategicstudiesinstitute.army.mil) 2.3.2 Components of Adversarial Air and Integrated Air Defense Systems (IADS) TR: AFTTP 3-1 All Volumes, Integrated Air and Missile Defense (IAMD) Operational Concept APP to C B JCD June 2008, FM 3-01, JP 1-02, JP 3-01, JP 3-05, Korean AOR Threat Reference Book June 2015, MCTP 10- 10B IADS, ADRP 1-02, FM 2-0 2.4 GI&S FUNDAMENTALS TR: : AFI 14-132; AFI 14-205, AFPAM 11-216, TC 3-25.26, AFTTP 3-4 2.4.1 Fundamentals and Uses of GI&S -- Pro

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.