Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

I cannot provide a specific answer because your question states only "UFC 4-212-01N" without asking a substantive question about the publication.

UFC 4-212-01N is Navy Engine Test Cells [UFC 4-212-01N title page], current as of 2006-07-27, including Chapter 4 as of September 2008. The passages provided contain fragments including restraint fitting figures, noise level requirements (85 dB maximum at 250 foot radius centered at engine tailpipe exit) [UFC 4-212-01N Appendix], and proofload test procedures for tie-down fittings [UFC 4-212-01N Appendix D].

To assist you, please ask a specific question about this UFC—for example, noise limits, restraint fitting types, inspection procedures, or proofload requirements.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
Show the 8 source passage(s) this answer is built from

AS Patuxent River, MD and NAS Jacksonville, FL. 24 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 Figure 5-2 Restraint Fitting, Type XI-A, Aircraft Run-p (+ Configuration) 25 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 Figure 5-3 Restraint Fitting Type XI-A, Aircraft Run-up (X Configuration) 26 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 Figure 5-4 Restraint Fitting Type F1, Aircraft Run-up Figure 5-5 Restraint Fitting Type F2, Aircraft Run-up 27 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 Figure 5-6 Restraint Fitting Type XIII, Aircraft Run-up 28 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 CHAPTER 6 INSPECTION, TEST PROCEDURES AND RECOMMNDED PROOF TEST ASSEMBLY FOR T-56 TUR

ecirculation in the cell. • Maximum noise level at 250 foot radius (centered at engine tailpipe exit) 85 dB. /4/ 42 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 APPENDIX C SAMPLE SUPPORTING STATEMENT TO WAIVER REQUEST 43 INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 APPENDIX D PROOFLOAD STATEMENT OF CONFORMANCE Proofload Statement of Conformance [Location] [Date] This statement attests to the satisfactory performance of the subject testing of tie-down fittings. [Type of test fitting] was tested with a load of [proofload test weight] in accordance with UFC 4-212-01 with a satisfactory test result. The [Name of organization supplying test equipment] attests that the gauges used during testing were calibrated within the past year in accordance with

UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 UNIFIED FACILITIES CRITERIA (UFC) NAVY ENGINE TEST CELLS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED INACTIVE UFC 4-212-01N July 27, 2006 Including Ch 4, September 2008 UNIFIED FACILITIES CRITERIA (UFC) NAVY ENGINE TEST CELLS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location 1 January 2007 Table 5-1; Paragraph 5-5.2.1.4 and 6-5.7. 2 April 2007 Figure 6-2; Paragraph 6-5.5 and 6-5.7.2. 3 No

UFC 3-260-01 as of 2019-02-04 · official source ↗

s://www.wbdg.org/dod/ufc UFC 4-211-01, Aircraft Maintenance Hangars: Type I and Type II, Naval Facilities Engineering \2\ Systems /2/ Command, https://www.wbdg.org/dod/ufc UFC 4-211-02, Aircraft Corrosion Control and Paint Facilities, Naval Facilities Engineering \2\ Systems /2/ Command, https://www.wbdg.org/dod/ufc \2\ UFC 4-212-01N, Navy Engine Test Cells, https://www.wbdg.org/dod/ufc /2/ UFC 4-832-01N, Design: Industrial and Oily Wastewater Control, Naval Facilities Engineering \2\ Systems /2/ Command, https://www.wbdg.org/dod/ufc \2\ UFGS 08 88 58, Air Traffic Control Tower Cab Glass, https://www.wbdg.org/dod/ufgs /2/ USACE TSC Report 13-2, Aircraft Characteristics for Military Aircraft, U.S. Army Corps of Engineers, https://transportation.wes.army.mil/tsmcx/criteria.aspx UFC 3-260-01

FC 2-000-05N as of 2026-02-11 · official source ↗

each side. Where multiple canopies are observed, each will have its own facility number and PRC. • In the “Notes” section of all associated PRCs, delineate the site location for references purposes. 214 56 GREASE RACK (EA) FAC: 2145 BFR Required: N CANCELED UFC 2-000-05N 200 Series - 191 21456-1 One grease rack (two vehicles) will be provided for each 125 vehicles. 215 MAINTENANCE - WEAPONS, SPARES 215-1 This group includes facilities for maintenance of small arms, automatic weapons, mortars, artillery guns, launchers, flamethrowers, torpedo tubes, harbor protective nets, and non-electronic equipment. See UFC 4-229-01N for design criteria. For missile maintenance facilities, see Category Group 212. 215 10 SMALL ARMS SHOP (SF) FAC: 2152 BFR Required: Y 21510-1 A small arms shop is used to s

UFC 4-141-10 as of 2022-09-22 · official source ↗

UFC 1-200-01 General Building Requirements UFC 2-000-05N Facility Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01 Architecture UFC 3-110-03 Roofing UFC 3-201-01 Civil Engineering UFC 3-220-01 Geotechnical Engineering UFC 3-250-01 Pavement Design for Roads and Parking Areas UFC 3-260-01 Airfield and Heliport Planning and Design UFC 3-260-04 Airfield and Heliport Marking UFC 3-301-01 Structural Engineering UFC 4-010-01 DoD Minimum Antiterrorism Standards for Buildings UFC 4-141-10 22 September 2022 6 UFC 4-022-03 Security Fences and Gates UFC 3-401-01 Mechanical Engineering UFC 3-410-01 Heating, Ventilating and Air Conditioning Systems UFC 3-420-01 Plumbing Systems UFC 3-450-01 Noise and Vibration Control UFC 3-460-01 Design: Petroleum Fuel Facilities UFC 3-501-01 El

UFC 4-711-01 as of 2018-08-10 · official source ↗

/dod/ufc /3/ UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements (applicable to multi-family housing) UFC 2-100-01, Installation Master Planning UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-120-10, Interior Design UFC 3-210-10, Low Impact Development UFC 3-301-01, Structural Engineering \3\ /3/ UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-450-01, Noise and Vibration Control UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-570-01, Cathodic Protection UFC 3-600-01, Fire Protection Engineering For Facilities UFC 3-810-01N, Navy and Marine Corps Environmental Engineering for Facility Construction UFC 4-01

UFC 3-530-01 as of 2023-02-09 · official source ↗

.wbdg.org/ffc/dod/unified-facilities-criteria-ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-490-06, Elevators UFC 3-535-01, Visual Air Navigation Facilities UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-021-02, Electronic Security Systems UFC 4-022-01, Security Engineering: Entry Control Facilities/Access Control Points UFC 4-025-01, Security Engineering: Waterfront Security UFC 4-152-01, Design: Piers and Wharves UFC 4-510-01, Design: Military Medical Facilities UFC 4-740-02, Fitness Centers UFC 4-7

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.