UFC 4-159-01N 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC) DESIGN: HYPERBARIC FACILITIES APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED INACTIVE UFC 4-159-01N 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC) DESIGN: HYPERBARIC FACILITIES Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEERING SUPPORT AGENCY Record of Changes (changes indicated by \1\ ... /1/ ) Change No. Date Location INACTIVE UFC 4-159-01N 16 January 2004 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, const
TERRORISM/FORCE PROTECTION. All DoD facilities must comply with UFC 4-010-01, Design: DoD Minimum Antiterrorism Standards for Buildings. If any conflict occurs between this UFC and UFC 4-010-01, the requirements of UFC 4-010-01 take precedence. INACTIVE UFC 4-159-01N 16 January 2004 A-1 APPENDIX A DESIGN MANUAL 39 HYPERBARIC FACILITIES INACTIVE ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿ ³ CCB Application Notes: ³ ³ ³ ³ 1. Character(s) preceded & followed by these symbols (À Ù) or (Ú ¿) ³ ³ are super- or subscripted, respectively. ³ ³ EXAMPLES: 42mÀ3Ù = 42 cubic meters ³ ³ COÚ2¿ = carbon dioxide ³ ³ ³ ³ 2. All degree symbols have been replaced with the word deg. ³ ³ ³ ³ 3. All plus or minus symbols have been replaced with the symbol +/-. ³ ³ ³ ³ 4. All table no
on Systems UFC 3-580-01, Telecommunications Interior Infrastructure Planning and Design UFC 3-600-01, Fire Protection Engineering for Facilities UFC 3-701-01, DoD Facility Pricing Guide UFC 3-730-01, Programming Cost Estimates for Military Construction UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-021-02, Electronic Security Systems \4\ UFC 4-026-01, Design to Resist Forced Entry /4/ UFC 4-510-01 03 February 2023 Change 4, 15 July 2025 473 UFC 4-159-01N, Design: Hyperbaric Facilities UNITED STATES ACCESS BOARD https://www.access-board.gov Architectural Barriers Act (ABA) Accessibility Standard for DoD Facilities, 23 July 2004 Architectura
BLICATIONS 1. Unified Facilities Criteria (UFC): http://dod.wbdg.org \1\ UFC 1-200-01, General Building Requirements UFC 3-220-01N, Geotechnical Engineering Procedures for Foundation Design of Buildings and Structures UFC 3-220-10N Soil Mechanics UFC 3-301-01, Structural Engineering UFC 3-570-02N, Electrical Engineering Cathodic Protection UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-025-01, Waterfront Security Design; currently in final draft and near final publication UFC 4-150-06, Military Harbors and Coastal Facilities UFC 4-150-07, Maintenance of Waterfront Facilities UFC 4-150-08, Inspection of Mooring Hardware UFC 4-151-10 10 September 2001 With Change 1, 1 September 2012 32 UFC 4-152-01, Design: Piers and Wharves UFC 4-159-03, Design: Moorings /1/ Unified Faciliti
dings UFC 4-020-01, DoD Security Engineering Facilities Planning Manual CANCELLED UFC 3-600-01 8 August 2016 Change 6, 6 May 2021 161 UFC 4-021-01, Design and O&M: Mass Notification Systems UFC 4-150-02, Dockside Utilities for Ship Service UFC 4-151-10, General Criteria for Waterfront Construction UFC 4-152-01, Design: Piers and Wharves UFC 4-159-01N, Design: Hyperbaric Facilities UFC 4-211-01, Aircraft Maintenance Hangars UFC 4-211-02, Aircraft Corrosion Control and Paint Facilities UFC 4-213-10, Design: Graving Drydocks UFC 4-213-12, Drydocking Facilities Characteristics UFC 4-215-01, Armories and Arms Rooms UFC 4-310-03, DoD Fuels Laboratory Standards UFC 4-510-01, Design: Medical Military Facilities UFC 4-740-06, Youth Centers UFC 4-740-14, Design: Child Development Centers UNITED STAT
3-220-01, Geotechnical Engineering UFC 4-152-01 24 January 2017 Change 1, 28 August 2024 161 UFC 3-301-01, Structural Engineering UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-570-01, Cathodic Protection UFC 4-025-01, Security Engineering: Waterfront Security UFC 4-150-02, Dockside Utilities for Ship Service UFC 4-150-06, Military Harbors and Coastal Facilities UFC 4-150-08, Inspection of Mooring Hardware UFC 4-152-07, Small Craft Berthing Facilities UFC 4-159-03, Moorings UFC 4-213-12, Dry Docking Facilities Characteristics UFC 4-860-03, Railroad Track Maintenance and Safety Standards UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) https://www.wbdg.org/ffc/dod/unified-facilities-guide-specifications-ufgs UFGS 03 31 29, Marine Concrete UFGS 35 59 13.16, Marine Fend
C 3-240-01, Wastewater Collection and Treatment UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-430-09, Exterior Mechanical Utility Distribution UFC 3-570-01, Cathodic Protection UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-025-01, Waterfront Security Design UFC 4-150-02, Dockside Utilities for Ship Service UFC 4-150-06, Military Harbors and Coastal Facilities UFC 4-152-01, Piers and Wharves UFC 4-159-03, Moorings UNIFIED FACILITIES GUIDE SPECIFICATIONS (UFGS) https://www.wbdg.org/ffc/dod UFGS 03 31 29, Marine Concrete with Service Life Modelling UFGS 03 31 30, Marine Concrete UFGS Division 26, Electrical UFGS 35 59 13.14 20, Polymeric Piles UFC 4-213-10 18 May 2020 137 U.S. ARMY CORPS
tant drains. Applicable criteria include UFC 3-401-01 for mechanical & UFC 3-410-01 for HVAC. Electrical Industrial equipment typically requires 240- and 480-volt, three-phase electrical current. Use commercial grade convenience receptacles and special power outlets. Consult X-ray and other NDI equipment specifications for their specific power requirements. Applicable criteria include UFC 3-501-01 for general electrical requirements, UFC 3-520-01 for interior electrical systems requirements, UFC 3-530-01 for interior and exterior lighting and controls requirements, UFC 3-550-01 for exterior power distribution systems requirements, UFC 3-560-01 for electrical safety and electrical O&M requirements, UFC 3-580-01 for building telecommunications requirements, and UFC 4-021-01 for mass notifica
NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.