Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

UFC 4-022-01 is the Unified Facilities Criteria document titled "Entry Control Facilities / Access Control Points," current as of 27 July 2017 [UFC 4-022-01]. It supersedes the previous version dated 25 May 2005 [UFC 4-022-01].

The document establishes that all Entry Control Facilities (ECFs) and Access Control Points (ACPs) must have a mechanism to conduct select inspections after the ID check area, with security requirements potentially mandating that all vehicles be inspected prior to entry [UFC 4-022-01]. Where random inspection activities occur, facilities and procedures must minimize impact to traffic flow on the main approach [UFC 4-022-01].

UFC 4-022-01 is referenced across multiple Air Force publications as the authoritative guidance on entry control facility design and operations, including in AFI 32-1023 for Antiterrorism compliance [AFI 32-1023 para 4.2.1.9] and in expeditionary force protection planning [AFPAM 10-219V2 para 8.1].

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
Show the 8 source passage(s) this answer is built from
UFC 4-022-01 as of 2017-07-27 · official source ↗

s, Engineering & Force Protection Deputy Assistant Secretary of Defense (Facilities Investment and Management) Office of the Assistant Secretary of Defense (Energy, Installations, and Environment) UFC 4-022-01 27 July 2017 This Page Intentionally Left Blank UFC 4-022-01 27 July 2017 i UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Subject: UFC 4-022-01, Entry Control Facilities / Access Control Points Cancels: UFC 4-022-01, Security Engineering: Entry Control Facilities / Access Control Points, dated 25 May 2005 Reasons for Revision: UFC 4-022-01 was updated for the following reasons: • To eliminate information that could be referenced from other references, especially tables, charts, figures, and diagrams. • To improve consistency and uniformity of terminology. • To remove ambig

UFC 4-022-01 as of 2017-07-27 · official source ↗

UFC 4-022-01 27 July 2017 UNIFIED FACILITIES CRITERIA (UFC) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED ENTRY CONTROL FACILITIES ACCESS CONTROL POINTS UFC 4-022-01 27 July 2017 ENTRY CONTROL FACILITIES ACCESS CONTROL POINTS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER CENTER Record of Changes (changes are indicated by ... ) Change No. Date Location This UFC supersedes UFC 4-022-01, dated 25 May 2005. UFC 4-022-01 27 July 2017 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, desig

UFC 4-022-01 as of 2017-07-27 · official source ↗

. All ECFs/ACPs must have a mechanism to conduct select inspections after the ID check area. In some cases, security requirements may require that all vehicles be inspected prior to entry. Where and when random inspection activities occur, facilities and procedures must be developed to minimize the impact to traffic flow on the main approach. UFC 4-022-01 27 July 2017 12 Figure 2-1 Visitors/DoD Personnel ECF/ACP – Functional Relationships Figure 2-2 DoD/Authorized Personnel Only ECF/ACP – Functional Relationships UFC 4-022-01 27 July 2017 13 Figure 2-3 Commercial Vehicle ECF/ACP: Functional Relationships UFC 4-022-01 27 July 2017 14 Figure 2-4 Primary ECF/ACP w/POV, Visitor, and Commercial Vehicle Processing UFC 4-022-01 27 July 2017 15 Table 2-2 ID #s for Figure 2-4 APPROACH ZONE ACCESS C

AFPAM 10-219V2 · para 8.1 as of 2021-02-22 · View in PDF → · official source ↗

e to Expeditionary Force Protection AFH 10-222V14 Civil Engineer Guide to Fighting Positions, Obstacles, and Revetments AFH 31-109 Integrated Defense in Expeditionary Environments AFI 31-101 Integrated Defense (FOUO) AFTTP 3-31.1 Entry Control (FOUO) ATP 3-37.34 Survivability Operations (FOUO) GTA 90-01-011 Joint Forward Operations Base (JFOB) Force Protection Handbook, Sixth Edition (FOUO) UFC 4-010-01 DOD Minimum Antiterrorism Standards for Buildings UFC 4-022-01 Entry Control Facilities/Access Control Points UFC 4-022-02 Selection and Application of Vehicle Barriers Chapter 8 BEDDOWN PREPARATIONS 8.1. General Information. Advance planning and preparation is necessary to beddown incoming military forces, disaster victims, or relief teams. Often, a beddown means providing facilities and u

AFI 32-1023 · para 4.2.1.10 as of 2025-11-24 · View in PDF → · official source ↗

s and Activities; AFMAN 32-7003, Environmental Conservation; and, for guidance and compliance requirements. 4.2.1.9. Antiterrorism. All DoD facilities must comply with the latest UFCs and directives governing Antiterrorism standards. (T-1). Refer to UFC 4-020-01, DoD Security Engineering Facilities Planning Manual, to establish Antiterrorism requirements. Refer to UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings, with Change 1, for minimum AT criteria for inhabited facilities. Refer to UFC 4-022-01, for further guidance on Entry Control Facilities. 4.2.1.10. Model Building Codes. Refer to UFC 1-200-01, DoD Building Code, with Change 1 and the United States Air Force Project Managers’ Guide for Design and Construction for specific guidance. AFI32-1023 23 DECEMBER 2020 19 4.2.

UFC 3-201-01 as of 2022-12-20 · official source ↗

FC 3-240-01, Wastewater Collection and Treatment UFC 3-250-01, Pavement Design for Roads and Parking Areas UFC 3-250-04, Standard Practice for Concrete Pavements CANCELLED UFC 3-201-01 20 December 2022 55 UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-260-02, Pavement Design for Airfields UFC 3-301-01, Structural Engineering UFC 3-420-01, Plumbing Systems UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-022-01, Security Engineering: Entry Control Facilities/Access Control Points UFC 4-022-02, Selection and Application of Vehicle Barriers UFC 4-152-01, Design: Piers And Wharves UFC 4-860-01, Railroad Design and Rehabilitation U.S. ARMY CORPS OF ENGIN

AFH 10-222 Volume 14 · para 2.1 as of 2008-08-01 · open official PDF ↗

otification Systems UFC 4-021-02 Security Engineering: Electronic Security Systems UFC 4-022-01 Entry Control Facilities/Access Control Points UFC 4-022-02 Design and Selection of Vehicle Barriers UFC 4-022-03/ Design of Security Fencing, Gates, Barriers, and MIL-HDBK-1013/10 Guard Facilities UFC 4-023-03 Design of Buildings to Resist Progressive Collapse UFC 4-023-04 Design of Windows to Resist Blast, Ballistics, and Forced Entry UFC 4-023-07 Design to Resist Direct Fire Weapons Effects UFC 4-026-01 Design to Resist Forced Entry UFC 4-027-01 Design of Deployed Operational Bases to Mitigate Terrorist AttacksAFH 10-222 Volume 14 1 August 2008 21 Chapter 2 FIGHTING POSITIONS 2.1. Overview. Fighting positions are fortified structures used for protection against hostile fire. They can also be

UFC 4-021-02 as of 2025-07-28 · official source ↗

s UFC 3-600-01, Fire Protection Engineering for Facilities UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-021-02 28 July 2025 207 UFC 4-010-03, Security Engineering: Physical Security Measures for High-Risk Personnel UFC 4-010-05, SCIF/SAPF Planning, Design, and Construction UFC 4-010-06, Cybersecurity of Facility-Related Control Systems (FRCS) UFC 4-020-01, DoD Security Engineering Facilities Planning Manual UFC 4-020-02FA, Security Engineering: Concept Design UFC 4-020-03FA, Security Engineering: Final Design UFC 4-022-01, Security Engineering: Entry Control Facilities/Access Control Points UFC 4-022-03, Security Fences and Gates UFC 4-024-01, Security Engineering: Procedures for Designing Airborne Chemical, Biological, and Radiological Protection for Buildings UFC

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.