Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

Governing guidance

Showing the controlling passages directly. (daily question limit reached — showing passages)

UFC 3-570-01 as of 2016-11-28 · official source ↗

ample Deep Anode Installation Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 146 Figure D-4 Example GCP Anode Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 147 Figure D-5 Example Seawater GCP Anode Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 148 Figure D-6 Example ICCP Oil Cooled Rectifier Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 149 Figure D-7 Example Anode Junction Box Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 150 Figure D-8 Example Flush Mount Test Station Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 151 Figure D-9 Example Flush Mount Bond Test Station Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 152 Figure D-10 Example Soil Access Test Station Detail UFC 3-

UFC 3-570-01 as of 2016-11-28 · official source ↗

, 14 January 2019 152 Figure D-10 Example Soil Access Test Station Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 153 Figure D-11 Example Dielectric Insulation Flange Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 154 Figure D-12 Example Exothermic Weld Detail UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 155 Figure D-13 Example Electrical One-Line Schematic Diagram

UFC 3-570-01 as of 2016-11-28 · official source ↗

ineering Command EDWIN H. OSHIBA, SES, DAF MICHAEL McANDREW Deputy Director of Civil Engineers DCS/Logistics, Engineering & Force Protection Director, Facilities Investment and Management Office of the Deputy Under Secretary of Defense (Installations and Environment) UFC 3-570-01 28 November 2016 Change 1, 14 January 2019 UNIFIED FACILITIES CRITERIA (UFC) NEW SUMMARY SHEET Document: UFC 3-570-01, Cathodic Protection Superseding: UFC 3-570-02A, Cathodic Protection, March 2005 UFC 3-570-02N, Electrical Engineering Cathodic Protection, Jan 2004 Description: This UFC provides general design guidance for cathodic protection (CP) systems. This UFC applies to all Army, Navy, and Air Force service elements and contractors. Reasons for Document: • Update the format of the manual (more of a policy a

CFETP 3E0X1WG · para 9.1.3.1 as of 2025-07-16 · open official PDF ↗

derground splices P pk - 8.5. Perform high potential DC test on P pk - underground cable 8.6. Troubleshoot underground cables P pk - for faults 8.7. Trace underground cables with P pk - cable test set 8.8. Isolate system faults P pk - 8.9. Fabricate load break elbow P pk - 8.10. Troubleshoot pad mount P pk - transformer 8.11. Construct distribution systems P pk - 9. DISTRIBUTION SYSTEMS, 600 VOLTS AND LESS TR: AFI 32-1062, AFI 32-1064, AFI 91-203; AFMAN 32-1083; NFPA 70, NFPA 70E; UFC 3-530-01, UFC 3- 570-06, UFC 3-570-02A Note: QTP required for UGT 9.1. Install 9.1.1. Service entrance P pk - 9.1.2. Service equipment 9.1.2.1. Meter base P pk - 9.1.2.2. Disconnect P pk - 9.1.3. Grounding 9.1.3.1. System P pk - 9.1.3.2. Equipment P pk - 9.1.3.3. Bonding P pk - 9.1.3.4. Feeders P pk - 9.1.3.5

UFC 3-460-01 as of 2019-07-16 · official source ↗

3, 08 June 2023 25 Corrosion Engineer to perform all cathodic protection design and testing. \2\ All designs will comply with UFC 3-570-01. /2/ 2-12.1 Tanks. For all underground steel tanks and tank bottoms of aboveground vertical tanks, provide cathodic protection in accordance with UFC 3-570-01, API RP 651, 40 CFR Part 280, UL 1746, and UFC 3-460-03. For additional information on cathodic protection, refer to UFC 3-460-03 and \2\ for Air Force follow AFI32-1001 /2/. Current tank design configuration electrically isolates the tank bottom from surrounding earth. Therefore, install cathodic protection between the liner and the tank bottom. 2-12.2 Piping. For all carbon steel and stainless steel underground and underwater piping, provide cathodic protection in accordance with UFC 3-570-01 a

AFI 32-1001 · para 15.6.1 as of 2025-03-04 · View in PDF → · official source ↗

. 15.5.7. To properly document cathodic protection performance, calibration, and operations, reference UFC 3-570-06, Operation and Maintenance: Cathodic Protection Systems. 15.6. Industrial Water Treatment. 15.6.1. Basic guidelines for industrial water treatment programs can be found in UFC 3-240- 01, Wastewater Collection and Treatment. This UFC provides guidance for testing procedures and frequency, backflow prevention devices, and non-chemical industrial water treatment. Consult AFMAN32-1067, Water and Fuel Systems, for additional information on proper use and handling of treatment chemicals and consult with the local base environment office prior to selecting and industrial water treatment chemicals. 15.6.2. Chemicals added to protect condensate lines from corrosion make the steam and

UFC 3-130-04 as of 2025-01-16 · official source ↗

es UFC 3-230-01, Water Storage, Distribution, and Treatment UFC 3-301-01, Structural Engineering UFC 3-301-02, Design of Risk Category V Structures, National Strategic Military Assets UFC 3-400-02, Design: Engineering Weather Data UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior and Exterior Lighting Systems UFC 3-540-01, Engine-Driven Generator Systems for Prime and Standby Power Applications UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-570-01, Cathodic Protection UFC 3-575-01, Lightning and Static Electricity Protection Systems UFC 3-580-01, Telecommunications Interior Infrastructure Plannin

UFC 1-200-01 as of 2022-09-01 · official source ↗

stribution Pipelines UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-490-06, Elevators UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-540-01, Engine-Driven Generator Systems for Prime and Standby Power Applications UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-560-01, Operation and Maintenance: Electrical Safety UFC 3-570-01, Cathodic Protection UFC 3-580-01, Telecommunications Interior Infrastructure Planning and Design UFC 3-600-01, Fire Protection Engineering for Facilities UFC 3-701-01, DoD Facilities Pricing Guide UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings \3\ UFC 4-010-05, SCIF/SAPF Planning, Design, and Construction /3/ UFC 4-010-06, Cyberse

NFPA standards (cited by reference)
NFPA 70 National Electrical Code — cited by CFETP 3E0X1WG (sections 5, 8) · read at NFPA free access ↗
NFPA 70E Electrical Safety in the Workplace — cited by CFETP 3E0X1WG (sections 2.3, 8.17) · read at NFPA free access ↗
NFPA 72 — cited by CFETP 3E0X1WG · read at NFPA free access ↗

NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.