Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.
Showing the controlling passages directly. (daily question limit reached — showing passages)
UFC 3-430-08N 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC) CENTRAL HEATING PLANTS APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED INACTIVE UFC 3-430-08N 16 January 2004 UNIFIED FACILITIES CRITERIA (UFC) CENTRAL HEATING PLANTS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER SUPPORT AGENCY Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location 1 Dec 2005 FOREWORD This UFC supersedes Military Handbook 1003/6, dated January 1991. INACTIVE UFC 3-430-08N 16 January 2004 FOREWORD \1\ The Unified Facilities Criteria (UF
E UFC 3-430-08N 16 January 2004 FOREWORD \1\ The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD(AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of forces Agreements (SOFA), Host Nation Funded Construction Agreements (HNFA), and in some instances, Bilateral Infrastructure Agreements (BIA.) Therefore, the acquisition team must ensure compliance with the more stringent of the UFC, the SOFA, the HNFA, and the BIA, a
y with UFC 4-010-01, Design: DoD Minimum Antiterrorism Standards for Buildings. If any conflict occurs between this UFC and UFC 4-010-01, the requirements of UFC 4-010-01 take precedence. INACTIVE UFC 3-430-08N 16 January 2004 A-1 APPENDIX A MIL-HDBK 1003/6 CENTRAL HEATING PLANTS INACTIVE +)))))))))))))), * INCH-POUND * .))))))))))))))- MIL-HDBK-1003/6 15 JANUARY 1991 SUPERSEDING DM-3.06 APRIL 1985 MILITARY HANDBOOK CENTRAL HEATING PLANTS AMSC/NA AREA FACR DISTRIBUTION STATEMENT A. APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED INACTIVE MIL-HDBK-1003/6 ii ABSTRACT Basic design guidance is presented for steam heating plants and high temperature water plants for use by architects and engineers. Criteria and design requirements are given for selection of fuel, solid and liquid fuel ha
nterior Design UFC 3-190-06, Protective Coatings and Paints UFC 3-201-01, Civil Engineering UFC 3-201-02, Landscape Architecture UFC 3-210-10, Low Impact Development UFC 3-220-01, Geotechnical Engineering UFC 3-230-01, Water Storage and Distribution UFC 3-230-03, Water Treatment UFC 3-240-01, Wastewater Collection and Treatment UFC 3-301-01, Structural Engineering UFC 3-301-02, Design of Risk Category V Structures, National Strategic Military Assets UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems CANCELLED UFC 1-200-01 01 September 2022 Change 4, 17 December 2024 71 UFC 3-420-01, Plumbing Systems UFC 3-430-05, Natural Gas and Liquefied Petroleum Gas (LPG) Distribution Pipelines UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-490-0
nt Framework for DoD Information Technology JOINT SERVICE http://www.wbdg.org/ccb/browse_cat.php?o=29&c=4 UFC 1-200-01, DoD Building Code (General Building Requirements) UFC 3-201-01, Civil Engineering UFC 3-230-02, Operation and Maintenance: Water Supply Systems UFC 3-240-05A, Solid Waste Incineration UFC 3-240-10A, Sanitary Landfill UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-301-01, Structural Engineering UFC 3-400-02, Design: Engineering Weather Data UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-04N, Industrial Ventilation UFC 3-420-01, Plumbing Systems UFC 3-540-08 23 January 2017 127 UFC 3-430-02FA, Central Steam Boiler Plants UFC 3-430-03, Air Pollution Control Systems for Boiler and Incinerators UFC
th the shore; a wharf is used for berthing or mooring vessels. May also be as above, except with continuous connection to shore. UFC 4-150-02 12 November 2020 201 REFERENCES F-1 GOVERNMENT PUBLICATIONS UNIFIED FACILITIES CRITERIA (UFC) https://www.wbdg.org/ffc/dod UFC 1-200-01, DoD Building Code UFC 3-190-06, Protective Coatings and Paints UFC 3-220-10N, Soil Mechanics UFC 3-230-01, Water Storage and Distribution UFC 3-400-02, Design: Engineering Weather Data UFC 3-430-09, Exterior Mechanical Utility Distribution UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-560-01, Electrical Safety Operation and Maintenance UFC 3-570-01, Cathodic Protection UFC 3-575
e UFCs for all aspects of design, including but not limited to: UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 2-100-01, Installation Master Planning UFC 3-130-01, Arctic and Subarctic Engineering UFC 3-130-02, Arctic and Subarctic Site Assessment and Selection UFC 3-130-03, Arctic and Subarctic Foundations for Freezing and Thawing Conditions UFC 3-130-04, Arctic and Subarctic Buildings UFC 3-201-01, Civil Engineering UFC 3-230-01, Water Storage, Distribution, and Treatment UFC 3-230-02, Operation and Maintenance: Water Supply Systems UFC 3-240-01, Wastewater Collection and Treatment UFC 3-410-02, Direct Digital Control for HVAC and Other Building Control Systems UFC 3-430-05, Natural Gas and Liquified Petroleum Gas (LPG) Distributi
Utility Monitoring & Control System (UMCS) Front End and Integration UFC 3-420-02 Compressed Air UFC 3-440-01 Facility-Scale Renewable Energy Systems Fueling Systems UFC 3-460-01 Design: Petroleum Fuel Facilities UFC 3-460-03 Petroleum Fuel Systems Maintenance MO-230 M&O of Petroleum Fuel Facilities UFC 3-410-04 Industrial Ventilation UFC 3-430-09 Exterior Mechanical Utility Distribution Central Plants UFC 3-430-11 Boiler Plant Instrumentation and Control Systems UFC 3-490-06 Elevators UFC 4-826-10 Design: Refrigeration Systems for Cold Storage UFC 3-430-01FA Heating & Cooling Distribution Systems CANCELLED UFC 3-401-01 28 July 2025 Change 2, 14 May 2026 3 CHAPTER 2 TECHNICAL REQUIREMENTS 2-1 DOCUMENTATION REQUIREMENTS Comply with the design analysis and drawing requirements in the UFC 3-4
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.