Ask a compliance question

Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.

UFC 3-410-01 was cancelled effective 28 July 2025 with Change 1 dated 23 January 2026. [UFC 3-410-01 title page]

The document addressed heating, ventilating, and air conditioning systems design, including HVAC system selection per UFC 1-200-02, corrosion control per UFC 1-200-01, and cybersecurity per UFC 4-010-06. [UFC 3-410-01 paras 2-1, 1-7] A UFC Supplement (UFS 3-410-01) provided supplemental information on best practices, design documentation, weather data, and Army policy regarding district and islanded energy plants, located under Related Materials at https://www.wbdg.org/dod/ufc/ufc-3-410-01. [UFC 3-410-01 para 1-8]

Since this publication is cancelled, consult your contracting officer or WBDG for replacement guidance or any transitional requirements.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.
Show the 8 source passage(s) this answer is built from
UFC 3-410-01 as of 2025-07-28 · official source ↗

-8 UFC SUPPLEMENT (UFS) 3-410-01. \1\ UFS 3-410-01 contains supplemental information including best practices, design documentation requirements, weather data access instructions, and Army policy information regarding district and islanded energy plants. UFS 3-410-01 is located under Related Materials on the UFC 3-410-01 webpage: https://www.wbdg.org/dod/ufc/ufc-3-410-01. /1/ CANCELLED UFC 3-410-01 28 July 2025 Change 1, 23 January 2026 3 CHAPTER 2 GENERAL DESIGN REQUIREMENTS 2-1 HVAC SYSTEM SELECTION. Comply with UFC 1-200-02 which provides requirements that influence the selection and design of heating, cooling, and ventilation systems and major system components. For Army projects, comply with Evaluation of District and Islanded/Decentralized Utility Options with Life-Cycle Cost Analysi

UFC 3-410-01 as of 2025-07-28 · official source ↗

UFC 3-410-01 28 July 2025 Change 1, 23 January 2026 UNIFIED FACILITIES CRITERIA (UFC) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS CANCELLED UFC 3-410-01 28 July 2025 Change 1, 23 January 2026 This Page Intentionally Left Blank CANCELLED UFC 3-410-01 28 July 2025 Change 1, 23 January 2026 UNIFIED FACILITIES CRITERIA (UFC) HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. Indicate the Military Department Preparing Activity responsible for the document. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND (Preparing Activity) AIR FOR

UFC 3-410-01 as of 2025-07-28 · official source ↗

026 2 component or system. UFC 1-200-01, section titled “Corrosion Prone Locations” identifies corrosive environments and humid locations requiring special attention. UFC 1-200-01, section titled “Requirements for Corrosion Prone Locations” provides examples of necessary actions. To determine Environmental Severity Classifications (ESC) for specific project locations refer to UFC 1-200-01 Appendix titled “ESC for DoD Locations”. 1-7 CYBERSECURITY. All facility-related control systems (including systems separate from a utility monitoring and control system) must be planned, designed, acquired, executed, and maintained in accordance with UFC 4-010-06, and as required by individual Service Implementation Policy. 1-8 UFC SUPPLEMENT (UFS) 3-410-01. \1\ UFS 3-410-01 contains supplemental informa

FC 4-218-01F as of 2015-10-28 · official source ↗

for Ground-Based C4I Facilities Performing Critical, Time-Urgent Missions (Part 1 - Fixed Facilities) UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-120-01, Design: Sign Standards UFC 3-120-10, Interior Design UFC 3-201-02, Landscape Architecture UFC 3-400-02, Design: Engineering Weather Data UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02, Lonworks® Direct Digital Control for HVAC and Other Local Building Systems UFC 3-410-04, Industrial Ventilation UFC 3-420-01, Plumbing Systems UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior

UFC 4-211-01 as of 2017-04-13 · official source ↗

OVERNMENT PUBLICATIONS UFC 3-260-01, Airfield and Heliport Planning and Design UFC 3-260-02, Pavement Design for Airfields UFC 3-260-04, (Draft) Standard Airfield Pavement Marking Schemes UFC 3-301-01 Structural Engineering UFC 3-310-04, Seismic Design for Buildings UFC 3-400-02, Design: Engineering Weather Data UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02, Direct Digital Control for HVAC and Other Local Building Systems, with Change 1 UFC 3-410-04N, Industrial Ventilation UFC 3-420-01, Plumbing Systems UFC 3-440-01, Facility-Scale Renewable Energy Systems UFC 3-510-01, Foreign Voltages and Frequencies Guide, with Change 2 UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Design: Interior and Exterior Lighting and

UFC 4-440-01 as of 2014-10-01 · official source ↗

must meet the requirements of UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems. 3-14.2.8 Heating Zones Provide heating zones to maximize energy savings and to meet sustainability requirements. 3-14.3 Ventilation Provide ventilation in accordance with UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems, and UFC 3-410-04N, Industrial Ventilation. UFC 4-440-01 1 April 2014 Change 1, 1 April 2019 76 Toxic fumes generated by gas powered fork trucks must be exhausted. It is recommended that gas powered fork trucks not operate inside the warehouse area. 3-14.4 Humidity Control Provide humidity control in accordance with UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems, and UFC 3-410-04N, Industrial Ventilation. 3-14.5 Air Conditioning Provide air condi

UFC 4-141-03 as of 2024-12-09 · official source ↗

itary Assets UFC 3-401-01, Mechanical Engineering UFC 4-141-03 09 December 2024 112 UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02, Direct Digital Control for HVAC and Other Building Control Systems UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-460-03, Petroleum Fuel Systems Maintenance UFC 3-501-01, Electrical Engineering UFC 3-510-01, Foreign Voltages and Frequencies Guide UFC 3-520-01, Interior Electrical Systems UFC 3-520-02, Facility Energy System Resilience and Reliability UFC 3-520-05, Stationary and Mission Batteries UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-540-01, Engine-Driven Generator Systems for Prime and Standby Power Applications UFC 3-560-01, Operation and Maintenance: Electrical Safety UFC 3-580-01, Tele

UFC 3-420-02 as of 2022-11-08 · official source ↗

Breathing Air Quality and Use UNIFIED FACILITIES CRITERIA https://www.wbdg.org/ffc/dod/unified-facilities-criteria-ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-02 8 November 2022 26 UFC 3-410-02, Direct Digital Control for HVAC and Other Building Control Systems UFC 3-450-01, Noise and Vibration Control UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings UFC 4-010-06, Cybersecurity of Facility-Related Control Systems UFC 4-510-01, Design: Military Medical Facilities UNIFIED FACILITIES GUIDE SPECIFICATION

Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.

Free · no spam

Get AFI changes and new cross-references by email

New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.