UFC 3-190-06 1 March 2021 UNIFIED FACILITIES CRITERIA (UFC) APPROVED FOR PUBLIC RELEASE; DISTRIBUTION UNLIMITED PROTECTIVE COATINGS AND PAINTS CANCELLED UFC 3-190-06 1 March 2021 UNIFIED FACILITIES CRITERIA (UFC) PROTECTIVE COATINGS AND PAINTS Any copyrighted material included in this UFC is identified at its point of use. Use of the copyrighted material apart from this UFC must have the permission of the copyright holder. Indicate the preparing activity beside the Service responsible for preparing the document. U.S. ARMY CORPS OF ENGINEERS NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND (Preparing Activity) AIR FORCE CIVIL ENGINEER CENTER Record of Changes (changes are indicated by \1\ ... /1/) Change No. Date Location This UFC supersedes UFC 3-190-06, dated 16 January 2004. CANCELLED UFC 3-
gistics, Engineering & Force Protection (HAF/A4C) HQ United States Air Force MICHAEL McANDREW Deputy Assistant Secretary of Defense (Construction) and Acting Deputy Assistant Secretary of Defense (Housing) Office of the Assistant Secretary of Defense (Sustainment) CANCELLED UFC 3-190-06 1 March 2021 UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 3-190-06, Protective Coatings and Paints Superseding: UFC 3-190-06, dated 16 January 2004 Description: This UFC provides requirements and technical guidance for the effective use of paint-type coatings to protect metal, concrete, gypsum board, and wooden structures at military activities from deterioration. This UFC applies to all Navy, Air Force, and Army service elements and contractors. Reasons for Document: • This versio
nes, follow current industrial practices. CANCELLED UFC 3-190-06 1 March 2021 21 3-3.12 Mildew Resistant Coatings. Mildewcides in paints are used to control mildew growth in the can and on the paint after application. Abate mildew growth on painted or unpainted surfaces of buildings, repair damaged areas, and clean substrates prior to applying a new or maintenance coating. 3-3.13 Pavement Markings. Use the UFGS for pavement markings to install markings and applicable products on airfield and road pavements. CANCELLED UFC 3-190-06 1 March 2021 22 This Page Intentionally Left Blank CANCELLED UFC 3-190-06 1 March 2021 23 CHAPTER 4 APPLICATION 4-1 GENERAL. Review coating suppliers Technical Data Sheets (TDS) or Product Data Sheets (PDS) and Safety Data Sheets (SDS) for each product to be used.
at DoD Owned or Operated Potable Water Treatment Plants, 18 Mar 2013. MIL-STD-3007, Standard Practice for Unified Facilities Criteria and Unified Facilities Guide Specifications, https://www.wbdg.org/dod/fedmil/mil-std-3007. OEBGD, Overseas Environmental Baseline Guidance Document, 1 May 2007. Unified Facilities Criteria, https://www.wbdg.org/dod/ufc UFC 1-200-01, DoD Building Code UFC 3-230-01, Water Storage, Distribution and Transmission UFC 3-420-01, Plumbing Systems UFC 3-600-01 Fire Protection Engineering for Facilities UFM 3-570-06, Operation and Maintenance: Cathodic Protection Systems UFM 3-601-02, Fire Protection Systems Inspection, Testing, and Maintenance UFS 3-190-06, Protective Coatings and Paints
P4400.105E, Radioactive Commodities in the DOD Supply Systems, http://www.dla.mil/issuances/Documents/i4145.8.pdf UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc. UFC 1-200-01, General Building Requirements UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 2-000-05N (P-80), Facilities Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-120-01, Design: Sign Standards UFC 3-120-10, Interior Design UFC 3-190-06, Protective Coatings and Paints UFC 3-201-01, Civil Engineering UFC 3-220-01, Geotechnical Engineering UFC 3-301-01, Structural Engineering UFC 3-310-04, Seismic Design for Buildings UFC Series 3-400, Mechanical UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-04N, I
nterior Design UFC 3-190-06, Protective Coatings and Paints UFC 3-201-01, Civil Engineering UFC 3-201-02, Landscape Architecture UFC 3-210-10, Low Impact Development UFC 3-220-01, Geotechnical Engineering UFC 3-230-01, Water Storage and Distribution UFC 3-230-03, Water Treatment UFC 3-240-01, Wastewater Collection and Treatment UFC 3-301-01, Structural Engineering UFC 3-301-02, Design of Risk Category V Structures, National Strategic Military Assets UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems CANCELLED UFC 1-200-01 01 September 2022 Change 4, 17 December 2024 71 UFC 3-420-01, Plumbing Systems UFC 3-430-05, Natural Gas and Liquefied Petroleum Gas (LPG) Distribution Pipelines UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-490-0
nuity Requirements Applicability: Directive and Guidance, https://www.wbdg.org/ffc/dod/engineering- and-construction-bulletins-ecb/usace-ecb-2012-16 UNITED STATES DEPARTMENT OF DEFENSE, UNIFIED FACILITIES CRITERIA PROGRAM http://dod.wbdg.org UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 1-300-02, UFGS Format Standard FC 1-300-09N, Navy and Marine Corps Design Procedures UFC 2-000-05N, Facility Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-120-10, Interior Design UFC 3-190-06, Protective Coatings and Paints UFC 3-400-02, Design: Engineering Weather Data UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-420-01, Plumbing Systems UFC 3-450-01, Noise and Vibration Control UFC 3-580-01 Telecommuni
th the shore; a wharf is used for berthing or mooring vessels. May also be as above, except with continuous connection to shore. UFC 4-150-02 12 November 2020 201 REFERENCES F-1 GOVERNMENT PUBLICATIONS UNIFIED FACILITIES CRITERIA (UFC) https://www.wbdg.org/ffc/dod UFC 1-200-01, DoD Building Code UFC 3-190-06, Protective Coatings and Paints UFC 3-220-10N, Soil Mechanics UFC 3-230-01, Water Storage and Distribution UFC 3-400-02, Design: Engineering Weather Data UFC 3-430-09, Exterior Mechanical Utility Distribution UFC 3-460-01, Design: Petroleum Fuel Facilities UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-560-01, Electrical Safety Operation and Maintenance UFC 3-570-01, Cathodic Protection UFC 3-575
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.