Plain English, any career field. Answers cite the AF pub + paragraph, your command's supplement, and the federal (OSHA/CFR) standard behind it — with the official PDF one click away.
NFPA text is copyrighted — we cite and link the official free-access viewer, never reproduce it.
quipment for routine maintenance. 11. Existing furniture must be inventoried for reuse and incorporated into the furniture layout when applicable. Any new furniture required must be compatible with and complementary to the existing furniture. CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 48 This Page Intentionally Left Blank CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 49 TEMPLATE FORMS FOR INTERIOR DESIGN SUBMITTALS Figure D-1 Navy FF&E Data Sheet TEMPLATE CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 50 Figure D-2 Army FF&E Data Sheet TEMPLATE - Standard CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 51 Figure D-3 Army FF&E Data Sheet TEMPLATE - HNC CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 52 This Page Intentionally Left Blank C
TT, P.E. Chief, Engineering and Construction Chief Engineer Directorate of Civil Works U.S. Army Corps of Engineers Naval Facilities Engineering Command EDWIN H. OSHIBA, SES, MICHAEL McANDREW Deputy Director of Civil Engineers DCS/Logistics, Engineering & Force Protection Deputy Assistant Secretary of Defense (Facilities Investment and Management) Office of the Assistant Secretary of Defense (Energy, Installations, and Environment) CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 UNIFIED FACILITIES CRITERIA (UFC) REVISION SUMMARY SHEET Document: UFC 3-120-10, Interior Design Superseding: • UFC 3-120-10, Interior Design, dated 15 June 2006, including Change 1, July 2007 Description: This UFC is a coordinated compilation of interior design requirements, and references non-government
/3/ WHOLE BUILDING DESIGN GUIDE, A PROGRAM OF THE NATIONAL INSTITUTE OF BUILDING SCIENCES Whole Building Design Guide, https://www.wbdg.org Criteria Change Request, https://cms.wbdg.org/ccrs/new?ufc=3-120-10 Indoor Air Quality and Mold Prevention of the Building Envelope http://www.wbdg.org/resources/indoor-air-quality-and-mold-prevention-building- envelope OMB Circular A131 Value Engineering, \3\ https://whitehouse.gov/wp- content/uploads/legacy_drupal_files/omb/circulars/A131/a131-122013.pdf /3/ USD (AT&L) Memorandum, \3\ https://www.wbdg.org/FFC/DOD/ufc_implementation.pdf /3/ CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 36 This Page Intentionally Left Blank CANCELLED UFC 3-120-10 16 May 2018 Change 3, 22 May 2025 37 TABLES Table B3-1 Design-Bid-Build Project Delivery Process
from facilities IAW NFPA 101. (T-0) Refer to UFC 3-600-01 for further guidance. 17.4.2.7. Directional signs, other than emergency exit signs, indicate the way to stairways, medical offices, health stations, emergency showers, etc., and will be designed IAW UFC 3-120-01. (T-0) 17.4.2.8. Instruction and identification signs designed IAW UFC 3-120-01 will be used to convey general instructions or identify PPE or systems. (T-0) 17.4.2.9. Laser hazard warning signs and labels will conform to and be used IAW AFI 48- 139. DoDI 6055.01, DoD Safety and Occupational Health (SOH) Program, outlines the military exemption for laser hazard communication. (T-0) 17.4.2.10. Radio Frequency Radiation Warning Signs. Radio frequency radiation warning signs signify the presence of hazardous electromagnetic en
, acoustics, and other environmental characteristics. CANCELLED UFC 1-200-01 01 September 2022 Change 4, 17 December 2024 19 2-12.2 Section 1206 – SOUND TRANSMISSION. 1206.2 Airborne sound [Replacement] Use UFC 3-101-01 and UFC 3-120-10. For Navy and Marine Corps Unaccompanied Housing facilities, only use FC 4-721-10N. 1206.3 Structure-borne sound [Replacement] Use UFC 3-101-01 and UFC 3-120-10. For Navy and Marine Corps Unaccompanied Housing facilities, only use FC 4-721-10N. 2-12.3 Section 1207 – ENHANCED CLASSROOM ACOUSTICS [REPLACEMENT]. Use UFC 3-101-01. 2-12.4 Section 1208 – INTERIOR SPACE DIMENSIONS. \4\ 1208.3 Dwelling Unit Size [Replacement] /4/ \4\ 1208.4 /4/ Room area [Replacement] Use UFC 3-101-01 and UFC 3-120-10. For Navy and Marine Corps Unaccompanied Housing facilities, onl
rating and provides specific guidance suitable for control systems assigned low or moderate impact level. 4.2.1.16. Interior Design. Refer to UFC 3-120-10, Interior Design. 4.2.1.17. Landscape Architecture. Refer to the Master Landscape Construction Specifications and UFC 3-201-02, Landscape Architecture, both available at the WBDG website, and the applicable installation’s Architectural Compatibility Plan. 4.2.1.18. Corrosion Prevention and Control Requirements. Provide design detailing, and use materials, systems, components, and coatings that are durable and minimize the need for preventative and corrective maintenance over the life-cycle of a facility. Provide a comprehensive corrosion prevention and control strategy. Many facility guide specifications include durable materials, coatin
for Ground-Based C4I Facilities Performing Critical, Time-Urgent Missions (Part 1 - Fixed Facilities) UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc UFC 1-200-01, DoD Building Code UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-120-01, Design: Sign Standards UFC 3-120-10, Interior Design UFC 3-201-02, Landscape Architecture UFC 3-400-02, Design: Engineering Weather Data UFC 3-401-01, Mechanical Engineering UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-02, Lonworks® Direct Digital Control for HVAC and Other Local Building Systems UFC 3-410-04, Industrial Ventilation UFC 3-420-01, Plumbing Systems UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior
P4400.105E, Radioactive Commodities in the DOD Supply Systems, http://www.dla.mil/issuances/Documents/i4145.8.pdf UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc. UFC 1-200-01, General Building Requirements UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 2-000-05N (P-80), Facilities Planning Criteria for Navy/Marine Corps Shore Installations UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-120-01, Design: Sign Standards UFC 3-120-10, Interior Design UFC 3-190-06, Protective Coatings and Paints UFC 3-201-01, Civil Engineering UFC 3-220-01, Geotechnical Engineering UFC 3-301-01, Structural Engineering UFC 3-310-04, Seismic Design for Buildings UFC Series 3-400, Mechanical UFC 3-410-01, Heating, Ventilating, and Air Conditioning Systems UFC 3-410-04N, I
⚠ Unofficial. Answers come from indexed publication text and may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Always verify against the official publication before acting, citing, or writing a finding.
New and updated AFIs, supplements, and OSHA cross-references as we index them — straight to your inbox.