eering and Construction Chief Engineer U.S. Army Corps of Engineers Naval Facilities Engineering Command TERRY G. EDWARDS, P.E. MICHAEL McANDREW Director, Air Force Center for Engineering and the Environment Director, Facility Investment and Management Department of the Air Force Office of the Deputy Under Secretary of Defense (Installations and Environment) CANCELLED UFC 3-110-03 1 May 2012 Change 5, 12 June 2020 UNIFIED FACILITIES CRITERIA (UFC) NEW DOCUMENT SUMMARY SHEET Subject: UFC 3-110-03, Roofing, dated 1 May 2012. Cancels: UFC 3-110-03, Roofing, dated 26 September 2006, UFC 3-320-03A, Structural Considerations for Metal Roofing, dated 1 March 2005 with Change 2 dated October 2010, UFC 3-330-02A, Commentary On Roofing Systems, dated 1 March 2005 and MIL-HDBK-1001/5, Roofing and Wat
tary On Roofing Systems, dated 1 March 2005 and MIL-HDBK-1001/5, Roofing and Waterproofing, dated 28 February 1990. Description of Changes: UFC 3-110-03 updates the roofing design criteria for DOD. Reasons for Changes: Updated to coordinate with the latest editions of the National Roofing Contractor Association’s Roofing Manual and Metal Building Manufacturer's Association Roofing Manual and to meet the latest DOD requirements. Impact: There are negligible cost impacts. However, the following benefits should be realized. • Elevates awareness that maintenance is necessary to achieve expected service life of roofing systems. • Makes UFC 3-110-04 rescindable by including pertinent criteria in this publication and updating references. CANCELLED UFC 3-110-03 1 May 2012 Change 5, 12 June 2020 i
For Installing Vegetative Green Roofs at CONUS Installations, dated 13 January 2011. CANCELLED UFC 3-110-03 1 May 2012 Change 5, 12 June 2020 This Page Intentionally Left Blank. CANCELLED UFC 3-110-03 1 May 2012 Change 5, 12 June 2020 FOREWORD The Unified Facilities Criteria (UFC) system is prescribed by MIL-STD 3007 and provides planning, design, construction, sustainment, restoration, and modernization criteria, and applies to the Military Departments, the Defense Agencies, and the DoD Field Activities in accordance with USD (AT&L) Memorandum dated 29 May 2002. UFC will be used for all DoD projects and work for other customers where appropriate. All construction outside of the United States is also governed by Status of Forces Agreements (SOFA), Host Nation Funded Construction Agreements
with non- combustible deck (no mechanically attached systems) Double redundant with concrete deck (no mechanically attached systems) Wind uplift resistance Greater of FM I-90 or UFC 3-110-03 Greater of FM I-90 or UFC 3-110-03 Greater of FM I- 120 or UFC 3- 110-03 Roof Slope IAW UFC 3-110-03 IAW UFC 3-110-03 IAW UFC 3-110- 03 UFC 4-141-03 09 December 2024 12 Grade 2 Grade 3 Grade 4 Doors and Windows F Fire rating IAW UFC 1-200-01 IAW UFC 1-200-01 IAW UFC 1-200- 01 Door size Minimum code requirements and not less than 36 in. (910 mm) wide and 96 in. (2400 m) high Minimum Code requirements (not less than 36 in. (910 mm) wide into computer, electrical, & mechanical rooms) and not less than 96 in. (2400 m) high Minimum Code requirements (not less than 48 in. (1200 mm) wide into computer, elect
ER 15 – ROOF ASSEMBLIES AND ROOFTOP STRUCTURES [SUPPLEMENT]. Use IBC Chapter 15 except as modified by UFC 3-110-03 and UFC 3-600-01. CANCELLED UFC 1-200-01 01 September 2022 Change 4, 17 December 2024 20 2-16 CHAPTER 16 – STRUCTURAL DESIGN [SUPPLEMENT]. Use IBC Chapter 16 except as modified below and by UFC 3-301-01 and 3-301-02. 2-16.1 Section 1604 – GENERAL DESIGN REQUIREMENTS. 1604.11 Fall prevention and protection [Addition] Provide fall protection features such as fixed ladders, roof hatches, handrails, guardrails and other building fall arrest systems in compliance with section titled “Hazard Prevention” in UFC 3-101-01. For fall protection features specific to roofing systems, provide in compliance with UFC 3-110-03. The anchorages and the structural elements that support these anch
o replace carry-off and evaporation. BOD, TSS, and HEM must all be Non- Detect. TDS levels must be in the range of 500 – 800 mg/L. UFC 4-214-03 17 March 2018 102 This Page Intentionally Left Blank UFC 4-214-03 17 March 2018 103 APPENDIX A REFERENCES UNIFIED FACILITIES CRITERIA http://www.wbdg.org/ccb/browse_cat.php?o=29&c=4 UFC 1-200-01, General Building Requirements UFC 1-200-02, High Performance and Sustainable Building Requirements UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-201-01, Civil Engineering UFC 3-401-01, Mechanical Engineering UFC 3-501-01, Electrical Engineering UFC 3-520-01, Interior Electrical Systems UFC 3-530-01, Interior and Exterior Lighting Systems and Controls UFC 3-550-01, Exterior Electrical Power Distribution UFC 3-580-01, Telecommunications Interior Inf
RAE Handbook–Fundamentals, Atlanta, GA NATIONAL FIRE PROTECTION ASSOCIATION https://www.nfpa.org/ NFPA 24, Standard for the Installation of Private Fire Service Mains and Their Appurtenances UNIFIED FACILITIES CRITERIA https://www.wbdg.org/dod/ufc UFC 1-200-01, DoD Building Code UFC 1-201-01, Non-Permanent DoD Facilities in Support of Military Operations UFC 2-100-01, Installation Master Planning UFC 3-101-01, Architecture UFC 3-110-03, Roofing UFC 3-130-04 30 September 2024 46 UFC 3-130-01, Arctic and Subarctic Engineering UFC 3-130-02, Arctic and Subarctic Site Assessment and Selection UFC 3-130-03, Arctic and Subarctic Foundations for Freezing and Thawing Conditions UFC 3-130-05, Arctic and Subarctic Utilities UFC 3-230-01, Water Storage, Distribution, and Treatment UFC 3-301-01, Struct
UFC 3-110-03 for inspection and maintenance requirements of pumphouse and filter building roof systems. 11-2.2 Canopies. Canopies are used to cover service station dispensers, containment basins, fuel truck loading and offloading equipment, and equipment installed in remote areas. 11-2.2.1 Inspection and Maintenance – Canopies. a. Inspect and maintain canopies in accordance with UFC 3-110-03. 11-3 SAFETY SHOWERS AND EYEWASH FOUNTAINS. Emergency safety showers and eyewash fountains are installed around fueling areas and pumphouses. They are typically equipped with an activation alarm that energizes a strobe light and horn. In some cases emergency eyewash/showers are equipped with tempered water systems that supply warm water to the emergency eyewash/shower. 11-3.1 Inspection and Maintenance