Q: UFC 4-022-01
UNOFFICIAL REFERENCE — VERIFY BEFORE CITING. This pack quotes indexed copies of public publications. The certified PDF on e-Publishing (linked under every quote) is the only authoritative source. Your MAJCOM/unit supplement may add stricter requirements.

Synthesized answer (unofficial)

UFC 4-022-01 (current as of 27 July 2017) is a Unified Facilities Criteria document that establishes requirements for Entry Control Facilities (ECFs) and Access Control Points (ACPs). [UFC 4-022-01 title page]

Key Requirements:

All ECFs/ACPs must have a mechanism to conduct select inspections after the ID check area. In cases where security requirements demand it, all vehicles must be inspected prior to entry. Where random inspection activities occur, facilities and procedures must be designed to minimize traffic flow impact on the main approach. [UFC 4-022-01 para 2]

Application in Air Force:

AFI 32-1023 directs all DoD facilities to comply with UFC 4-022-01 for guidance on Entry Control Facilities as part of antiterrorism standards. [AFI 32-1023 para 4.2.1.9, 4.2.1.10]

The document was revised in 2017 to eliminate redundant information from other references, improve terminology consistency, and remove ambiguities from the prior 2005 version. [UFC 4-022-01 Revision Summary]

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.

Controlling Air Force guidance (quoted)

AFPAM 10-219V2 para 8.1, p. 91 (effective/current as of 2021-02-22)

e to Expeditionary Force Protection AFH 10-222V14 Civil Engineer Guide to Fighting Positions, Obstacles, and Revetments AFH 31-109 Integrated Defense in Expeditionary Environments AFI 31-101 Integrated Defense (FOUO) AFTTP 3-31.1 Entry Control (FOUO) ATP 3-37.34 Survivability Operations (FOUO) GTA 90-01-011 Joint Forward Operations Base (JFOB) Force Protection Handbook, Sixth Edition (FOUO) UFC 4-010-01 DOD Minimum Antiterrorism Standards for Buildings UFC 4-022-01 Entry Control Facilities/Access Control Points UFC 4-022-02 Selection and Application of Vehicle Barriers Chapter 8 BEDDOWN PREPARATIONS 8.1. General Information. Advance planning and preparation is necessary to beddown incoming military forces, disaster victims, or relief teams. Often, a beddown means providing facilities and u

Official source: https://static.e-publishing.af.mil/production/1/af_a4/publication/afpam10-219v2/afpam10-219v2.pdf View in PDF →
AFI 32-1023 para 4.2.1.10, p. 28 (effective/current as of 2025-11-24)

s and Activities; AFMAN 32-7003, Environmental Conservation; and, for guidance and compliance requirements. 4.2.1.9. Antiterrorism. All DoD facilities must comply with the latest UFCs and directives governing Antiterrorism standards. (T-1). Refer to UFC 4-020-01, DoD Security Engineering Facilities Planning Manual, to establish Antiterrorism requirements. Refer to UFC 4-010-01, DoD Minimum Antiterrorism Standards for Buildings, with Change 1, for minimum AT criteria for inhabited facilities. Refer to UFC 4-022-01, for further guidance on Entry Control Facilities. 4.2.1.10. Model Building Codes. Refer to UFC 1-200-01, DoD Building Code, with Change 1 and the United States Air Force Project Managers’ Guide for Design and Construction for specific guidance. AFI32-1023 23 DECEMBER 2020 19 4.2.

Official source: https://static.e-publishing.af.mil/production/1/af_a4/publication/afi32-1023/afi32-1023.pdf View in PDF →
AFH 10-222 Volume 14 para 2.1 (effective/current as of 2008-08-01)

otification Systems UFC 4-021-02 Security Engineering: Electronic Security Systems UFC 4-022-01 Entry Control Facilities/Access Control Points UFC 4-022-02 Design and Selection of Vehicle Barriers UFC 4-022-03/ Design of Security Fencing, Gates, Barriers, and MIL-HDBK-1013/10 Guard Facilities UFC 4-023-03 Design of Buildings to Resist Progressive Collapse UFC 4-023-04 Design of Windows to Resist Blast, Ballistics, and Forced Entry UFC 4-023-07 Design to Resist Direct Fire Weapons Effects UFC 4-026-01 Design to Resist Forced Entry UFC 4-027-01 Design of Deployed Operational Bases to Mitigate Terrorist AttacksAFH 10-222 Volume 14 1 August 2008 21 Chapter 2 FIGHTING POSITIONS 2.1. Overview. Fighting positions are fortified structures used for protection against hostile fire. They can also be

Official source: https://static.e-publishing.af.mil/production/1/publication/afh10-222v14/afh10-222v14.pdf

Supplement deltas

No supplement passage retrieved — check the supplement chain on the pub page before citing.

Federal / DoD standards implemented (quoted)

No federal/DoD passage retrieved.