# UFC 3-101-01 Status

UFC 3-101-01 has been CANCELLED as of 16 December 2020 [UFC 3-101-01]. This was the Unified Facilities Criteria document for Architecture that unified architectural criteria for DOD, superseding the prior version dated 28 November 2011 with Changes 1-5 [UFC 3-101-01].

Despite its cancellation, UFC 3-101-01 remains referenced in active Air Force publications. Current standards direct users to consult UFC 3-101-01 for specific requirements including sound transmission [UFC 1-200-01 para 1206.2, 1206.3], enhanced classroom acoustics [UFC 1-200-01 para 1207], interior space dimensions and room area [UFC 1-200-01 para 1208.3, 1208.4], and glazing and daylighting design [UFC 3-101-01].

For current architectural guidance, refer to the superseding document or contact the official source, as the current authoritative version is not provided in these passages.

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.

Controlling Air Force guidance (quoted)

DAFMAN 91-203, p. 180 (effective/current as of 2026-06-25)

roducts Systems Including Hydrocarbon Missile Fuels Color code for pipelines, piping systems and compressed gas cylinders Current MIL-STD-101, DoD Standard Practice: Color Code for Pipelines and for Compressed Gas Cylinders ASME A13.1, Scheme for the Identification of Piping Systems Signs design UFC 3-120-01, Design: Sign Standards Exit signs NFPA 101, Life Safety Code UFC 3-600-01, Fire Protection Engineering for Facilities Fire hazards signs NFPA 704, Standard System for the Identification of the Hazards of Materials for Emergency Response Electrical equipment labeling UFC 3-560-01, Operation and Maintenance: Electrical Safety Signs and symbols for explosive materials DESR 6055.09_DAFMAN 91-201, Explosives Safety Standards Laser hazard warning signs AFI 48-139, Laser and Optical Radiatio

Official source: https://static.e-publishing.af.mil/production/1/af_se/publication/dafman91-203/dafman91-203.pdf View in PDF →
DAFI 32-2001 para 7.2.4.1.3, p. 44 (effective/current as of 2026-04-01)

clude missing fire protection systems or missing NFPA 101 features in any building or process. Any facility FSD which is non-compliant with the following is considered an FSD I: 7.2.4.1.1. New Facilities. New facilities must meet the requirements specified in UFC 3-600-01. (T-0) Such facilities must not be considered as complete and usable until the deficiency is corrected. (T-2) 7.2.4.1.2. For Modernized, Renovated, Repaired, Restored, Upgraded and Change-of- Occupancy Facilities, these facilities must meet the requirements of UFC 3-600-01. (T-0) 7.2.4.1.3. Existing Facilities. Existing facilities must meet the minimum requirements of NFPA 101 for existing occupancies in accordance with UFC 3-600-01. (T-0) 7.2.4.1.4. Impairments. Identified fire safety feature impairments for existing occ

Official source: https://static.e-publishing.af.mil/production/1/af_a4/publication/dafi32-2001/dafi32-2001.pdf View in PDF →
DAFI 32-1020 para 2.2, p. 33 (effective/current as of 2026-02-10)

award phase, up to and including project award. See Table 2.1 for UFC 3-600-01 programming compliance metrics. (T-1) Note: The entire facility must, at all times, meet NFPA 101 minimum requirements. (T-0) Table 2.2. UFC 3-600-01, Fire Protection Engineering for Facilities, Compliance Metrics. UFC Term UFC Definition Abridged UFC rule Repair Patching, restoring, painting to maintain sound condition Work area must comply to UFC Renovation Replacement, strengthening, or upgrading not resulting in reconfiguration of space Work area must comply to UFC Modification Reconfigurations Work area must comply; If 50% area, entire facility must comply Reconstruction Reconfiguration affecting exit or shared corridor Entire building must comply Addition An increase in area Addition must comply Change in

Official source: https://static.e-publishing.af.mil/production/1/af_a4/publication/dafi32-1020/dafi32-1020.pdf View in PDF →

Supplement deltas

No supplement passage retrieved — check the supplement chain on the pub page before citing.

Federal / DoD standards implemented (quoted)

No federal/DoD passage retrieved.

NFPA standards (cited by reference — copyrighted, not quoted)

Retrieval confidence: 71.94 · Generated by CheckMyAFI — an unofficial reference. Not an official Air Force product. Verify every citation against the certified publication.