# Compliance evidence pack (UNOFFICIAL)

- **Question:** UFS 3-600-01
- **Generated:** 2026-07-21 19:56 UTC
- **e-Publishing catalog checked:** 2026-07-12
- **Supplement layer:** none selected
- **Source:** CheckMyAFI (https://checkmyafi.com) — unofficial reference

> **UNOFFICIAL — VERIFY BEFORE CITING.** Quotes come from indexed copies of public publications. The certified PDF on e-Publishing is the only authoritative source. Your MAJCOM/unit supplement may be stricter.

## Controlling Air Force guidance (quoted)

**DAFMAN 91-203 para 24.14.2.1, p. 272** (effective/current as of 2026-06-25)

> ticle 513, Standard on Aircraft Hangars, NFPA 409, Standard on Aircraft Hangars, NFPA 410, UFC 3-600-01, and associated engineering technical letters (ETLs) for detailed design guidance. Note 1: ETLs supplement UFC 3-600-01 and compliance with ETLs is required per AFI 32-1023, Designing and Constructing Military Construction Projects. Note 2: ETLs take precedence in conflicts with national fire codes, building codes or UFC 3-600-01. 24.14.2.1. Fixed electrical equipment approved for Class I, Division 1 locations may be used in Class I, Division 2 locations of the same class and compatibility group. Equipment not meeting these guidelines will be de-energized or disabled and locked out until special operations are complete and hazardous conditions permanently eliminated. (T-1) Refer to parag

Official source: https://static.e-publishing.af.mil/production/1/af_se/publication/dafman91-203/dafman91-203.pdf

**DAFI 32-2001 para 7.2.4.1.3, p. 44** (effective/current as of 2026-04-01)

> clude missing fire protection systems or missing NFPA 101 features in any building or process. Any facility FSD which is non-compliant with the following is considered an FSD I: 7.2.4.1.1. New Facilities. New facilities must meet the requirements specified in UFC 3-600-01. (T-0) Such facilities must not be considered as complete and usable until the deficiency is corrected. (T-2) 7.2.4.1.2. For Modernized, Renovated, Repaired, Restored, Upgraded and Change-of- Occupancy Facilities, these facilities must meet the requirements of UFC 3-600-01. (T-0) 7.2.4.1.3. Existing Facilities. Existing facilities must meet the minimum requirements of NFPA 101 for existing occupancies in accordance with UFC 3-600-01. (T-0) 7.2.4.1.4. Impairments. Identified fire safety feature impairments for existing occ

Official source: https://static.e-publishing.af.mil/production/1/af_a4/publication/dafi32-2001/dafi32-2001.pdf

## Supplement deltas

_No supplement passage retrieved — check the supplement chain before citing._

## Federal / DoD standards implemented (quoted)

_No federal/DoD passage retrieved._

## NFPA standards (cited by reference — copyrighted, not quoted)

- **NFPA 70** National Electrical Code — cited by DAFMAN 91-203 — official viewer: https://link.nfpa.org/free-access/publications/70/latest
- **NFPA 30** Flammable and Combustible Liquids Code — cited by DAFMAN 91-203 — official viewer: https://link.nfpa.org/free-access/publications/30/latest
- **NFPA 70E** Electrical Safety in the Workplace — cited by DAFMAN 91-203 — official viewer: https://link.nfpa.org/free-access/publications/70E/latest
- **NFPA 101** Life Safety Code — cited by DAFI 32-2001 — official viewer: https://link.nfpa.org/free-access/publications/101/latest

---
Retrieval confidence: 95.54 · CheckMyAFI is not an official Air Force product. Verify every citation against the certified publication.