## Synthesized answer (unofficial)

UFC 3-340-02 is a Unified Facilities Criteria document titled "Structures to Resist the Effects of Accidental Explosions" [UFC 3-340-02]. 

The current version is dated 5 December 2008 with Change 2 issued 1 September 2014 [UFC 3-340-02]. Change 2 rescinded changes to section 4-55 and figure 4-65a that had been mistakenly based on SI units in Change 1, restoring them to match the original 5 December 2008 version using U.S. customary units [UFC 3-340-02]. Change 1 (1 July 2014) had revised section 4-55 and figure 4-65a to incorporate updated spall and breach thresholds for reinforced concrete walls and implemented major revisions to masonry analysis and design guidance in sections 6-7, 6-8, and 6-9 [UFC 3-340-02].

The document superseded earlier publications: Army TM 5-1300, Navy NAVFAC P-397, and Air Force AFR 88-22 [UFC 3-340-02]. It is referenced as the governing standard for blast analysis and design calculations in Air Force construction criteria [DESR 6

Unofficial — answered from indexed publication text, which may be incomplete or out of date. Your MAJCOM/unit supplement may be stricter. Verify the official PDF before acting or writing a finding.

## Controlling Air Force guidance (quoted)

**DESR 6055.09 DAFMAN 91-201, p. 208** (effective/current as of 2025-06-18)

> itical structural elements. (T-1) V2.E5.1.7.3.3. (Added)(DAF) All applicable electrical, grounding, and LPS details. (T- 1) DESR 6055.09, Edition 1, Change 1, February 23, 2024 VOLUME 2 – ENCLOSURE 5: CONSTRUCTION CRITERIA PERMITTING REDUCED SEPARATION DISTANCES 208 V2.E5.1.7.3.4. (Added)(DAF) Supporting blast analysis, experimental data reports, blast design calculations, and other technical information. (T-1) Blast analysis and design calculations must satisfy UFC 3-340-02 requirements. (T-1) V2.E5.1.7.3.5. (Added)(DAF) A memorandum from the submitting DAFCOM civil engineer, or Air Force Installation and Mission Support Center Detachment Commander, verifying that the protective construction design modifications comply with this manual and UFC 3-340-02 requirements. (T-0) Base verificatio

Official source: https://static.e-publishing.af.mil/production/1/af_se/publication/desr6055.09_dafman91-201/desr6055.09_dafman91-201.pdf

**SSCMAN 91-710V7** (effective/current as of 2023-09-06)

> romagnetic Radiation Hazards, February 1, 2005 T.O. 42C-1-11, Cleaning and Inspection Procedures for Ballistic Missile Systems, September 25, 1980 Note: This technical order has been cancelled, with no replacement. The Standards of the Hydraulic Institute UFC 1-200-01, DoD Building Code, October 8, 2019, Change 1 (October 1, 2020) UFC 3-301-01, Structural Engineering, October 1, 2019, Change 1 (February 4, 2022) UFC 3-340-02, Structures to Resist the Effects of Accidental Explosions, with Change 2, September 1, 2014 UFC 3-520-01, Interior Electrical Systems, with Change 2, April 12, 2021 UFC 3-600-01, Fire Protection Engineering for Facilities, with Change 6, May 6, 2021 UL 558 (2012, revised in 2021), Standard for Safety, Industrial Trucks, Internal Combustion Engine-Powered UL 583 (2012,

Official source: https://static.e-publishing.af.mil/production/1/ssc/publication/sscman91-710v7/sscman91-710v7.pdf

## Supplement deltas

_No supplement passage retrieved — check the supplement chain before citing._

## Federal / DoD standards implemented (quoted)

_No federal/DoD passage retrieved._

---
Retrieval confidence: 100.0 · CheckMyAFI is not an official Air Force product. Verify every citation against the certified publication.